CHAPTER 5: Remote Control
Priorities
The NET main input (ch 1 - 32 in mode 5, ch 1 - 64 in modes 2-4) has always priority.
The unit will only switch onto the backup input if there is a valid trigger signal while
there is none or one with lower priority on the NET input.
BLDS™ has priority over pilot tone.
'BLDS'™ > 'Pilot tone' > 'no trigger'
Switching result table
Main Backup Output
BLDS™ BLDS™ Main
BLDS™ pilote tone Main
BLDS™
no trigger
Main
pilote tone BLDS™ Backup
pilote tone pilote tone Main
pilote tone
no trigger
Main
no trigger
BLDS™ Backup
no trigger
pilot tone Backup
no trigger no trigger
Main
EARS™ - Force Mode
To override automatic switching temporarily, the source for the output can be
forced to MAIN or BACKUP. The selection becomes available once EARS™ is
activated.
Force Mode can be helpful if you want to stay with one system as a source while
testing the second one.
Source Pull-down menu to adjust the Force Mode.
Values:
Auto = automatic switch-over active
Force Main = switch-over inactive, source Main
Force Backup = switch-over inactive, source Backup