Appendix C - Working with ch 57 mode
Appendix C - Working with ch 57
mode
Channel mode 57 ch on the MADI output enables
transparent pass-through of embedded control data
that is used by DiGiCo consoles.
Ch 57 mode is detected at the MADI input
automatically and signaled to the user.
To preserve the control data throughout the signal
chain:
set MADI output to 57 ch mode
route input channel 57 to output channel 57
The control data is preserved also across a Dante
connection to another EXBOX.MD, where it is output
to MADI.
NOTE
The incoming control data is neither examined nor
altered by the EXBOX.MD.