CHAPTER 5: Remote Control
Priorities
The Dante main input (ch 1 - 32 in mode 5, ch 1 - 64
in modes 2-4) has always priority. The unit will only
switch onto the backup input if there is a valid trigger
signal while there is none or one with lower priority
on the Dante input.
BLDS™ has priority over pilot tone.
'BLDS™' > 'Pilot tone' > 'no trigger'
Switching result table
Main Backup Output
BLDS™ BLDS™ Main
BLDS™ pilote tone Main
BLDS™
no trigger
Main
pilote tone BLDS™ Backup
pilote tone pilote tone Main
pilote tone
no trigger
Main
no trigger
BLDS™ Backup
no trigger
pilot tone Backup
no trigger no trigger
Main