page 62 of 94 EXBOX.MD Manual - Version 1.7
CHAPTER 5: Remote Control
EARS™ - Triggering
The EXBOX.MD supports two kinds of trigger signals:
• BLDS™ (generated by the BLDS™ Generator)
• Pilot tone (audio signal with a level higher than
-40 dBFS).
Switching by BLDS™ trigger is immediate (between
two samples). The Pilot tone is evaluated for 10ms
before switching is triggered.
Mode Main trigger Backup trigger
2 - 4 Dante ch 64
(ch 32 @ 2FS)
MADI ch 64
(ch 32 @ 2FS)
5 Dante ch 32
(ch 16 @ 2FS)
Dante ch 64
(ch 32 @ 2FS)
The trigger at the MADI input is expected according
to the selected mode (2 = SFP, 3 = BNC, 4 = SC).
NOTE
With the FastSRC™ activated at the Dante I/O the
trigger signal detection of EARS™ is limited to Pilot
tone - see "Sample Rate Conversion" on page 36.