CHAPTER 4: Operation
The clock source of the device is adjusted via the
remote control. Open the control page in a browser
by entering the device's IP address.
PTP configuration is available in the tab 'Clock Status'
of the software 'Dante Controller' from Audinate.
PTP sync is handled by the Dante network
automatically. EXBOX.MD can act as a PTP slave or
Grandmaster (preferred master).
Sync to External
When clocking to a source other than PTP, make sure
to enable the 'Enable Sync to External' option for this
device. The unit should also be 'preferred master'
then to make sure that the Dante network is in sync
with the system clock of EXBOX.MD.
Information about clocking in Dante network
environments is available on the Audinate website:
https://www.audinate.com/resources/faqs