Manual

page 31 of 40EXBOX.64 Manual - Version 2.0
CHAPTER 5: Application Examples
CHAPTER 5: Application Examples
Signal Conversion
The input signal from MADI 1 input (optical) is fed to
MADI 2 output (coaxial). MADI 2 input (coaxial) is fed
to MADI 1 output (optical).
Range Extension
The input signal is fed to MADI 2 input (coaxial).
As the MADI 1 port (optical) is bridged the signal is
output at the MADI 2 output (coaxial). It is refreshed
electrically and re-clocked offering a range extension
of cable length.
MADI 1 (SC)
IN OUT
MADI 2 (BNC)
IN OUT
MADI 2 MADI 1
MADI 1 (SC)
IN OUT
MADI 2 (BNC)
IN OUT
MADI 2