Installation guide
DirectOut Technologies
®
page 22 of 30 © 2012 DirectOut GmbHD.O.TEC
®
M.1k2 Hardware & Installation Guide - Version 1.1
Appendix A
Appendix A
Emergency recovery
There is one static network configuration which you cannot modify,
it is called ‘Factory preset’. If you somehow managed to create a
dysfunctional set of network settings or cannot reach the device for
other reasons, you can always return to the factory preset via the
front panel.
Procedure: Press the RESET button on the front panel for about
5s. As soon as you press the button, it will start ashing rapidly. If it
stops ashing, the factory preset has been activated. You can then
access the device via the initial IP address (10.0.0.24).
The LED STATE indicates the operating condition:
LED Operating condition
Constant on The controller is idle (normal operation).
Heartbeat The controller is idle (normal operation).
Blinking once
per second
The factory default network
settings are active.
This state should only be active when
configuring the device for the first time, or
after the RESET button has been pressed.
You can configure the network in
Configuration → Device → Network settings.
Blinking 4 times
per second
There is unsaved configuration data.
After the changes have been written
safely to the ash memory, the state
LED returns to the idle state.