Installation guide

DirectOut Technologies
®
page 16 of 30 © 2012 DirectOut GmbHD.O.TEC
®
M.1k2 Hardware & Installation Guide - Version 1.1
CHAPTER 4: Operation
Device State & RESET
As most of the system information is available in the GUI (or a telnet
shell) only, the basic system state is indicated by the LEDSTATE.
If the device can’t be reached via network an emergency recovery
may be executed using the RESET button (see „Appendix A“ on
page 22).
STATE LED (green) indicates
current system state.
LED ON = controller is idle
(normal operation)
LED “heartbeat” = controller is
idle (normal operation)
LED blinking once per second = factory
default network setting is active
LED blinking 4 times per second = unsaved
configuration data, device will return to idle
state after saving to the ash memory.
RESET Push button
Press and hold >5s for emergency recovery.
The behaviour of the LED “STATE” may be configured in the GUI
(see the “Software Guide”).