DirectOut Technologies D.O.TEC® M.1k2 Hardware & Installation Guide Version 1.
DirectOut Technologies® Copyright Note Copyright All rights reserved. Permission to reprint or electronically reproduce any document or graphic in whole or in part for any reason is expressly prohibited, unless prior written consent is obtained from the DirectOut GmbH. All trademarks and registered trademarks belong to their respective owners.
DirectOut Technologies® Table of Contents Table of contents About This Manual 5 How to Use This Manual Conventions 5 5 CHAPTER 1: Overview 6 Introduction Feature Summary Applications 6 6 7 CHAPTER 2: Legal issues & facts Before Installing This Device Defective Parts/Modules First Aid (in case of electric shock) Contents Updates Intended Operation Conditions of Warranty Conformity & Certificates Contact CHAPTER 3: Installation Installing the Device Network integration 8 8 8 9 10 10 10 10 11 11 1
This page is left blank intentionally.
DirectOut Technologies® About This Manual About This Manual How to Use This Manual This manual guides you through the installation and operation of the M1k2. For information about the graphical user interface (GUI) please consult the “Software Guide”. Use the Table of Contents at the beginning of the manual or Index Directory (page 30) to locate help on a particular topic. You can access more information and latest news by visiting on the DirectOut website at www.directout.eu.
DirectOut Technologies® CHAPTER 1: Overview CHAPTER 1: Overview Introduction The M.1k2 is a 16 port MADI router. It provides routing of whole ports down to single channel level offering a 1024 by 1024 crosspoint matrix. You can distribute MADI signals en bloc in a port matrix and you may also create your own MADI stream using the channel matrix. PolySync™ provides the ability to use different clock sources on individual ports.
DirectOut Technologies® USB Port USB 2.0 port for virtual COM port (RS232) Power Supply This device is equipped with two wide range power supplies (84 V to 264 V AC / 47 Hz to 63 Hz / safety class 1). CHAPTER 1: Overview Applications M.1k2 can be used for distribution and creation of whole MADI streams, routing of single audio channels between MADI streams and independent routing of embedded serial data and MIDI data. .
DirectOut Technologies® CHAPTER 2: Legal issues & facts CHAPTER 2: Legal issues & facts Before Installing This Device Warning Please read and observe ALL of the following notes before installing this product: • Check the hardware device for transport damage. • Any devices showing signs of mechanical damage or damage from the spillage of liquids MUST NOT be connected to the mains supply, or disconnected from the mains immediately by pulling out the power lead. • All devices MUST be grounded.
DirectOut Technologies® CHAPTER 2: Legal issues & facts First Aid (in case of electric shock) Warning • DO NOT touch the person or his/her clothing before power is turned off, otherwise you risk sustaining an electric shock yourself. • Separate the person as quickly as possible from the electric power source as follows: 99 Switch off the equipment. 99 Unplug or disconnect the mains cable. • Move the person away from the power source by using dry insulating material (such as wood or plastic).
DirectOut Technologies® CHAPTER 2: Legal issues & facts Contents The contents of your M.1k2 package should include: • 1 x M.1k2 (19’’, 2 RU) • 2 x power chord • 2 x fixing unit for power plug • 1 x Manual Updates D.O.TEC® products are continually in development, and therefore the information in this manual may be superseded by new releases. To access the latest documentation and firmware, please visit the DirectOut website: www.directout.eu. Intended Operation The M.
DirectOut Technologies® CHAPTER 2: Legal issues & facts Conformity & Certificates CE This device complies with the basic requests of applicable EU guidelines. The appropriate procedure for approval has been carried out. RoHS (Restriction of the use of certain Hazardous Substances) This device was constructed fulfilling the directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002/95/EC.
DirectOut Technologies® CHAPTER 3: Installation CHAPTER 3: Installation Installing the Device 1. Open the packaging and check that the contents have been delivered complete and undamaged. 2. Fix the device in a 19’’ frame with four screws, or place it on a non-slip horizontal surface. Warning Avoid damage from condensation by waiting for the device to adapt to the environmental temperature.
DirectOut Technologies® CHAPTER 3: Installation 4. Using the power cords provided connect both PSUs to a matching power supply: Warning This device MUST be connected to the mains using the three-cord power leads supplied with the system. Only supply the voltages and signals indicated (84 V – 264 V). 5. Turn on the power switch and check the status of PSUs on the front panel: Keep any packaging in order to protect the device should it need to be dispatched for service. 6.
DirectOut Technologies® CHAPTER 3: Installation Network integration To set up your D.O.TEC® M.1k2 initially (or after a reset) you need a working IP connection with the controller of the device. The M.1k2 is delivered with a fixed IP address. So first you will have to change the network settings of your computer to setup the IP connection. An online wizard will guide through all necessary steps then. For some basics about networking see page 26.
DirectOut Technologies® CHAPTER 4: Operation CHAPTER 4: Operation Introduction This chapter describes the basic operation of the device. Note that throughout this manual, the abbreviation FS refers to sample rate or sample frequency. So, when dealing with scaling factors, the following sample rates can be written as: • 44.1 kHz = 1 FS; 88.2 kHz = 2 FS ; 176 kHz = 4 FS or • 48 kHz = 1 FS; 96 kHz = 2 FS; 192 kHz = 4 FS Global Control The control on the right of the front panel indicates the power supply.
DirectOut Technologies® CHAPTER 4: Operation Device State & RESET As most of the system information is available in the GUI (or a telnet shell) only, the basic system state is indicated by the LED “STATE”. If the device can’t be reached via network an emergency recovery may be executed using the RESET button (see „Appendix A“ on page 22). STATE LED (green) indicates current system state.
DirectOut Technologies® CHAPTER 4: Operation User data (Serial, MIDI, GPO) For remote application and signalling purposes there are connection possibilities for RS 232 / 422 / 485, MIDI and General Purpose Output (GPO). Serial signals can be routed either by using userbits1 of a MADI frame. 4 GPOs can be triggered manually or automatically by a system event. RS 232 DSUB-9 socket (male) Connect RS 232 signal here. Observe the correct pin assignment.
DirectOut Technologies® CHAPTER 4: Operation Clocking The M.1k2 may use a variety of clock sources: internal (44.1 kHz / 48 kHz), word clock, video (PAL / NTSC) or a specific MADI input port. The system may be operated with one clock source only or may use different clock sources at a time (PolySync™). That means that one can use a bunch of ports with clock source ‘A’ while another portion is clocked by clock source ‘B’. The selected clock source is output at both word clock outputs.
DirectOut Technologies® CHAPTER 4: Operation Remote Operation The M.1k2 may be controlled via an ethernet connection or serial data input. Ethernet RJ45 socket Connection for ethernet control Requires a standard CAT5 cable for connection with ethernet network (100 mbit/s). USB USB socket USB connection for virtual serial port. Requires a standard USB cable (Type B). To use the USB port as virtual serial port the D.O.TEC USB driver1 (Windows 7, Vista, XP) has to be installed on the computer first.
DirectOut Technologies® CHAPTER 5: Technical Data CHAPTER 5: Technical Data Dimensions • Width 19’’ (48.26 cm) • Height 2 HE (8.9 cm) • Depth 10’’ (25.4 cm) Weight • about 4 kg Power Consumption • typical 0.2 A (@84 V) up to max. 0.1 A (@264 V) • max. 0.4 A (@84 V) up to max. 0.
DirectOut Technologies® CHAPTER 5: Technical Data Sample Rate • 30 - 50 kHz @1 FS • 60 - 100 kHz @2 FS • 120 - 200 kHz @4 FS MADI Format (I/O) • 48k Frame, 96k Frame • 56 channel, 64 channel • S/MUX 2/4 Word Clock • 1 x BNC socket (75 Ω impedance) - input • 2 x BNC socket (75 Ω impedance) - output • WCLK signal • Termination 75 Ω switchable Video • 1 x BNC socket (75 Ω impedance) - input MIDI • 2 x DIN socket (input / output) Serial Communication • RS-232 • RS 422 / RS 485 General Purpose Output (GP
DirectOut Technologies® Appendix A Appendix A Emergency recovery There is one static network configuration which you cannot modify, it is called ‘Factory preset’. If you somehow managed to create a dysfunctional set of network settings or cannot reach the device for other reasons, you can always return to the factory preset via the front panel. Procedure: Press the RESET button on the front panel for about 5s. As soon as you press the button, it will start flashing rapidly.
DirectOut Technologies® Appendix B Appendix B DSUB-9 Pin assignments RS232 The RS232 port handles bitrates of 9600, 19200, 38400 and 115200 bps without RTS/CTS support. 5 1 4 2 9 6 3 8 7 2 4 7 8 1 5 6 9 jack - male Pin Signal 2 RX 3 TX 5 GND RS4xx The RS4XX port can be configured to handle RS422 or RS485 signals and bitrates of 9600, 19200, 38400 and 115200 bps.
DirectOut Technologies® Appendix C Appendix C Installing / Replacing I/O modules Three different modules are available to fit in to the two slots of the M.1k2. If necessary the modules may be replaced or swapped executing the following steps. Requirements: • I/O module • Screwdriver (Phillips 1) The installation of the module does not require to open the device. The module is inserted at the front side of the device.
DirectOut Technologies® Appendix C Modules BNC - Module (coaxial) SC - Module (optical) SFP - Module (optical) © 2012 DirectOut GmbH ® D.O.TEC M.1k2 Hardware & Installation Guide - Version 1.
DirectOut Technologies® Appendix D Appendix D How to - Network The following guide aims to familiarize with basic information to setup a TCP-IP network. Some terms and techniques are explained to conduct you through the first steps. Terms IP Address - Address of a device within your local network. Must be unique. Example: 192.168.74.15 or 10.0.0.24 Gateway - Address of the network router. When connecting only two devices ‘peer to peer’, use the ip address of one device if it is needed to be declared.
DirectOut Technologies® Appendix D In a network environment each device (computer, printer, D.O.TEC® M.1k2…) needs its own and unique IP address. This can be achieved by a manual setup or by using a DHCP server within a network. The use of a DHCP may ease up the administration of a network. However, if fixed and known addresses are a need, it is helpful to set up a network manually. Example 1 - Peer to Peer IP Adress: 10.0.0.20 Network Mask: 255.255.255.0 Gateway: 10.0.0.20 DNS: 8.8.8.8 IP Adress: 10.
DirectOut Technologies® Appendix E Appendix E Firmware Update Instruction This instruction describes the firmware update procedure for the M.1k2. Requirements • D.O.TEC ® M.1k2 • Network access to the M.1k2 • Access to the admin account of the controller It is recommended that you backup the configuration data of the device (Configuration - Backup/Restore in the GUI) before performing the firmware update procedure. Installation 1. Download the update file (“M.1k2 Firmware”) at: http://www.directout.
DirectOut Technologies® Appendix E 5. Select “Begin update”. The file will be uploaded, checked and detailed update information will be shown after a few seconds. Please read this carefully! 6. Confirm the update with “Begin update!”. The update process may take several minutes. While updating the device is not accessible and audio will not be processed. After update the device is rebooted automatically. The network configuration remains unchanged. 7. After the update you need to log in again.
DirectOut Technologies® Index Index P Peer to Peer See Network C Pinout Cable Specifications________________ 21 GPO ����������������������������������������������������������� 23 RS232 �������������������������������������������������������� 23 RS422/485 ������������������������������������������������ 23 Conditions of Warranty see Warranty Conformity & Certificates____________ 11 CE ��������������������������������������������������������������� 11 RoHS ����������������������������������������������