CHAPTER 4: Operation
Connecting Word clock
The word clock output provides the system clock that is either derived from AES
input, word clock input, MADI input or internal clock generator.
WCK
OUT
BNC socket (coaxial), 75 Ω
System clock output - connect for word clock output signal here.
WCK
IN
BNC socket (coaxial), 75 Ω
Connect word clock or AES3 DARS (Digital Audio Reference
Signal) here.
The word clock input also accepts a AES3 frame (AES11).
Termination (75 Ω) for the word clock input is switchable locally or via remote
control.
Connecting USB
The USB port is used for fi rmware updates and for remote control.
USB USB socket (Type B)
Connect for fi rmware updates and remote control here.
The use of the USB port requires the USB Serial driver installed. The driver and the
installation instructions are available at the ANDIAMO.AES product page at
www.directout.eu.