Manual
Table Of Contents
page 24 of 48 ANDIAMO.AES (SRC) Hardware Guide - Version 2.0
CHAPTER 4: Operation
Clocking
Selectable clock sources are word clock, AES input MADI input or the internal
clock. LEDs on the front panel inform about selection and sync state of the
selected source. The current system clock is provided at the word clock output.
The clock setting can be altered via remote control or locally -
see „System Settings“ on page 39.
INT LED (green): indicates use of internal clock
generator as clock source
LED ON = Clock source set to internal clock
generator
AES* LED (green): indicates use of AES as clock
source
LED ON = Clock source set to AES input
LED blinking = Clock source set to AES and no signal
present (or all SRCs switched on).
WCK LED (green): indicates use of word clock as
clock source
LED ON = Clock source set to word clock
LED blinking = Clock source set to word clock and no
signal present
LED blinking pattern = signal locked but not in sync
75 Ω LED (yellow): indicates the termination status
of word clock input.
LED ON = Termination enabled
LED OFF = Termination disabled
MADI LED (green): indicates use of MADI input as
clock source
LED ON = Clock source set to MADI input
LED blinking = Clock source set to MADI input and no
signal present
SYNC** LED (green): indicates the lock/sync status of
selected MADI input
LED ON = MADI input signal is in sync
LED blinking = MADI input signal of is locked but not in
sync