Manual

Table Of Contents
page 71 of 140Prodigy.MC Manual - Version 2.4
CHAPTER 5: Managing Device
LEVEL METER - INPUT (MIC8.LINE.IO)
The LEVEL METER - INPUT (MIC8.LINE.IO) displays:
Level meters for a single converter slot - 8 channels
Slot number and module type inserted
control for input level, mute and phantom power (depending on the module)
Tap / click to
Arrow left navigate to previous module*
Arrow right navigate to next module*
INPUT SLOT return to HOME screen
Trim** / Gain select field(s) for modifying values of trim and gain.
selected unselected
48 V phantom power (48 V)
enabled disabled
PAD enable / disable PAD (-9 dB MIC8 / - 30 dB MIC8.HD)
enabled disabled
* the arrows are used for circular navigation through slots 1 to 4 input, followed
by slot 1 to 4 output.
** displayed with a yellow background, when the value is not zero
To adjust the level:
select field(s)
turn the Encoder or use the arrow keys (left and right)
un-select field(s) when finished
to zero the value, press the Encoder
Values:
Gain: module dependent
Trim: from - 24 dB to + 24 dB
48 V
PAD
48 V
PAD