Specifications

© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
C-1
C Buep 19e-Expander driverC Buep 19e-Expander driver
C1 First commissioning
Preface The successful parameterization of the PCS as described in the PCS
091/991/925/995 manual is presupposed. This appendix relates
exclusively to the use of the PCS micro/mini/midi and plus together with
the BOSCH CL200/CL400/CL500 PLC via the programming interface by
means of the BUEP19E protocol. In the following, this controller is referred
to as programmable controller and the driver to be loaded into the PCS
as 5P90BUEP. The BOSCH specific terminology and the programming
of the programmable controller with the BOSCH software are presupposed
as known.
Attention!
Use only the software PCSPRO or PCSPRO
WIN
for programming. Other
software packages can release failures of the PCS and PLC.
The following products are required for the operation of a programmable
controller with an PCS (Systeme Lauer company):
1. PCS 009/090/095/900/920/950/950c/PCS plus operating console
2. The PCS 706 connecting cable for the PCS to programmable con-
troller connection via the TTY interface or a zero-modem cable for
the connection via the RS-232C interface
3. PCSPRO floppy disk with 5P90BUEP driver, version 1.3 or later
4. PCS 091/925/995 manual
5. PCS 91.BOS appendix including BOSCH handling software floppy
disk
Furthermore are required (BOSCH company):
1. Programming card, programming cable, software (version 3.12 or
later) and the copy protection device for programming the PLC
2. CL500/CL400/CL200 racks
3. Power supply NT 3
4. Coordinator board SK 500 (not for CL400/CL200)
5. One or several ZS 500 CPU boards (with 32k or 64k RAM module)
6. One or several I/O boards
7. Power supplies for the PCS console and Bosch I/O boards