Specifications

© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-32
A LAUER driver
A4 Technical apendix
A4.1 PCS 830.3
This part of the manual contains special informations which are reqiered
for the setup: cable assignment, transfer addresses and a short explanation
of the data transfer using the communication port and the I/O bus.
Mechanical design Board with 64-pole DIN 41612 „C“ connector
Power supply Via motherboard: 12 V
Current requirement 300 mA max. (typically 250 mA)
Address allocation 12 addresses in the EZ/AZ area;
4 successive addresses (selectable via
DIL-switches) in the additional I/O area (EZ/AZ)
with EZ/AZ-addresses lying in parallel
Interfaces 3 x TTY (20 mA)
TTY current sources Internal/external selectable
Potential separation Yes, optocouplers hp 4100/4200
Dimensions 233.4 * 160 * 30 mm
Front elements 3 7-segment status displays „St.x“
3 LED „TXx“ = transmit current
3 LED „RXx“ = receive current
3 JD female connector „TTY1“
3-pole inline connector (RIA, 24V, earth, 0V)
Current source supply 24V DC (current requirement 50 mA max.)
stabilized
Connections 24V, earth, 0V (potentially isolated)