User manual
DEI PVM-4210 
Document Number 9100-0201 Rev 8 
 Directed Energy, Inc. 2000-2002 
Page 12 
      -Input trigger voltage too low. 
      -Input trigger pulse width too short. Increase 
  width. 
      -Input trigger frequency too high. Reduce  
  frequency. 
      -No input high voltage. Check HV supplies. 
-Enable circuit not satisfied. Ensure that +5VDC 
 is applied to DSUB pin 14. 
-No gate polarity is selected. DSUB pins 9 & 10 or 
pins 10 &11 must be connected. 
      -Output not connected correctly. Check all cables 
  and connections. 
      -Pulser is damaged. Contact DEI customer 
  service. 
6.2 Factory Service 
If the procedures above fail to resolve an operational problem, please 
contact the factory for further assistance: 
DIRECTED ENERGY, INC. 
2401 RESEARCH BLVD SUITE 108 
FORT COLLINS, CO 80526 
(970) 493-1901 FAX (970) 493-1903 
7.0 WARRANTY 
There are no warranties, express or implied, including any implied 
warranty of fitness for a particular purpose nor any IMPLIED WARRANTY 
OF MERCHANTIBILITY made by Directed Energy, Inc. (DEI) except as 
follows: 
DEI warrants equipment manufactured by it to be free from defects in 
materials and/or workmanship under conditions of normal use for a period 
of one year from the date of shipment to the purchaser. DEI will repair or 
replace, at DEI's option, any product manufactured by it which is shown to 
be defective or fails to perform within specifications within one year from 
the date of shipment to the purchaser. OEM, modified and custom items of 
equipment are similarly warranted, for a period of ninety (90) days from 
date of shipment to the purchaser. 
Equipment claimed to be defective must be returned, transportation 
prepaid, to DEI's factory in Fort Collins, Colorado within the warranty 
period. Returns must be preauthorized by contact with DEI's customer 
service department. Written documentation of such preauthorization shall 
be included with the returned item. 