User manual
DEI PVM-4210 
Document Number 9100-0201 Rev 8 
 Directed Energy, Inc. 2000-2002 
Page 11 
2. Connect the input DSUB connector, and connect the output to an 
appropriate load, prior to applying +24VDC power. 
3. Monitor the voltage across the load, utilizing an appropriate high voltage 
probe or attenuator. 
4. Apply +24VDC to +28VDC power to the module, and apply a TTL level 
power supply enable signal (or close the switch to connect pin 3 to pin 
14 as described above). The module should produce positive and 
negative output pulses with an amplitude equal to the power supply 
voltage, with a pulse width and pulse recurrence frequency following 
that of the incoming gate. 
5. Adjust the output voltages using the power supply adjustment 
potentiometers. The voltage of each channel is independently 
controlled. If only one channel will be used, set the voltage of the 
unused channel to zero. 
6. If there is no output from the module, disable the high voltage power 
supplies. Leave the module connected to the +24VDC input without high 
voltage and with all connectors in place for approximately one minute to 
bleed off the stored energy, then disconnect the +24VDC power to the 
unit and refer to the Troubleshooting Section of this manual. 
6.0 TROUBLESHOOTING 
WARNING 
The module contains capacitors that are used as energy storage elements. 
When charged, these capacitors contain in excess of 0.02 joules of stored 
energy. This is sufficient energy to cause injury. Assure that the +24VDC 
power is disconnected from the pulser, and that the capacitor bank is fully 
discharged and a shorting strap installed before any repairs or adjustments 
are attempted. Verify with a voltmeter that all circuits are de-energized 
before servicing. Dangerous voltages, floating ground planes and energy 
storage exist at several locations in the module. Touching connections or 
components could result in serious injury. 
6.1 Troubleshooting Procedures
The table below summarizes potential problems and their solutions. If these 
recommendations do not resolve the problem, DEI customer service can be 
contacted for further assistance. 
SYMPTOM   SOLUTIONS 
1. No output pulse.    -No input trigger. 