Install guide
Rev.: 20111215
Platform: DBALL
Firmware: NISS01
Vehicle CAN Bus Integration System
The Mobile Integration Systems
© 2011 Directed Electronics. All rights reserved.
Page 3
Not required in D2D mode.
** Parking Lights be W2W in Viper/Python/Clifford 4X02/5X02 platform systems, This platform does not support D2D parking light message.MUST
* Tach wire is an optional connection required on some remote starters, which do not support a tach signal in D2D.
(-) Trunk Status Input
(-) Door Status Input
(-) Neutral Safety Input/(-) Handbrake Status Input
Remote
Starter
(-) GWR (Status)
(+) Ignition 1 Output
(+) Ignition 2 Output
(+) Parking Lights Output**
(-) Trunk Output
(-) Unlock Output
(-) Lock Output
(+) 12v
(-) Ground
(+) Starter (2x if required)
10
DBALL
RF
Programming button
LED
9:Pink: (+) Ignition Input
10:Blue/White: (-) GWR (Status) Input
1: Green: (-) Lock Input
2: Blue: (-) Unlock Input
3: Red/White: (-) Trunk Input
7: Pink/White: (+) Parking Lights Input**
4
14
12
2
3:Tan/Black: HSCAN High
4:Tan: HSCAN Low
10:Orange/Red
11:Yellow/Red
13:Red: (+) 12v(+) 12v
14:Black: (-) Ground(-) Ground
3: Green/White: (-) Door Status Output
4: Red/Black: (-) Trunk Status Output
5: Violet/White: (AC) Tach Output*
6: Gray: (+) Brake Output
(AC) Tach Input*
(+) Brake Input
(-) Hood Status Input
1: Black/White: (-) Handbrake Status Output
12: Blue/Red: (-) Hood Status
2: Green/Black: (-) Auto Headlamp Shutoff
P#: XKD2D65
TX
(-) Ground
RX
(+)12v
Wire Side View
of BCM
To LED
Auto Headlamp Shutoff connection:
See Wiring Reference Chart (page 4) to
know which connection type to use
according to your vehicle on page 10.
A relay must be added to prevent starter damage on certain model. Refer
to the Wiring Reference Chart on page 4 to know which IPDM-E/R wiring
chart to use with your vehicle. Also refer to the Vehicle Wiring Reference
Chart to see where the BCM is located in each vehicle.
This installation type does control the OEM alarm.
See feature 3 of the Feature and Option List to disable the OEM alarm and avoid issues.
NOT
Installation Type 1
(+) Accessory (2x if required)
Wires are listed by pin numbers. This display is not representative of connector pin layouts, which are often stacked.
With the exception of the OBII Diagnotistic plug, all connectors are displayed from the wire side.