Specifications
54 
Sonar Menu with Sensitivity command selected (left). 
Sensitivity Control Bar (right). 
NOTE: 
If you want to change the sensitivity in Manual Mode, turn off Auto
Sensitivity. From the Sonar Page, press 
MENU|↓ to AUTO SENSITI
V
-
ITY
|ENT|↑ to SENSITIVITY|ENT. Press ↓ or ↑ to pick a different sensi-
tivity setting. When it is set at the desired level, press 
EXIT. 
Tip: 
While you are experimenting and learning, it is possible to scram-
ble the settings so the sonar picture disappears from the screen. I
f
that happens, remember it is easy to switch back to full automatic
operation by restoring the factory default settings. 
To Restore Factory Settings 
1. Press 
MENU|MENU|↓ to SYSTEM SETUP|ENT|↓ to RESET OP-
TIONS
|ENT. 
2. A reset options confirmation message will appear. Select 
YES
an
d
press  ENT. All options are reset and the unit reverts back to the
original settings. 