User manual
Table Of Contents
- Agilent 1260 Infinity Quaternary Pump VL
- In This Guide...
- Introduction
- Site Requirements and Specifications
- Installing the Pump
- Using the Quaternary Pump
- Optimizing Performance
- Troubleshooting and Diagnostics
- Error Information
- What are Error Messages
- General Error Messages
- Module Error Messages
- Restart Without Cover
- Pressure Above Upper Limit
- Pressure Below Lower Limit
- Pressure Signal Missing
- Valve Failed (MCGV/SSV)
- Inlet-Valve Fuse
- Valve Fuse
- Missing Pressure Reading
- Pump Configuration
- Motor-Drive Power
- Encoder Missing
- Inlet-Valve Missing
- Temperature Out of Range
- Temperature Limit Exceeded
- Servo Restart Failed
- Pump Head Missing
- Index Limit
- Index Adjustment
- Index Missing
- Stroke Length
- Initialization Failed
- Wait Timeout
- Solvent Zero Counter
- Degasser: cannot read signal
- Degasser: limit not reached
- Test Functions and Calibration
- Maintenance
- Introduction to Maintenance
- Warnings and Cautions
- Overview of Maintenance
- Cleaning the Module
- Checking and Cleaning the Solvent Filter
- Exchanging the Passive Inlet Valve (PIV)
- Exchanging the Outlet Valve
- Exchanging the Purge Valve Frit
- Removing the Pump Head Assembly
- Maintenance of a Pump Head Without Seal Wash Option
- Seal Wear-in Procedure
- Maintenance of a Pump Head with Seal Wash Option
- Reinstalling the Pump Head Assembly
- Exchanging the Multi-Channel Gradient Valve (MCGV)
- Exchanging the Optional Interface Board
- Exchanging the Active Inlet Valve (AIV) or its Cartridge
- Replacing the Module Firmware
- Parts and Materials for Maintenance
- Identifying Cables
- Appendix
- In This Book

1260 Infinity QP VL User Manual 167
Identifying Cables
11
Remote Cables
Agilent Module to 3396 Series III / 3395B Integrators
Agilent Module to Agilent 35900 A/D Converters
p/n 03396-61010 Pin 33XX Pin Agilent
module
Signal Name Active
(TTL)
9 1 - White Digital ground
NC 2 - Brown Prepare run Low
3 3 - Gray Start Low
NC 4 - Blue Shut down Low
NC 5 - Pink Not connected
NC 6 - Yellow Power on High
14 7 - Red Ready High
4 8 - Green Stop Low
NC 9 - Black Start request Low
13, 15 Not connected
p/n 5061-3378 Pin 35900 A/D Pin Agilent
module
Signal Name Active
(TTL)
1 - White 1 - White Digital ground
2 - Brown 2 - Brown Prepare run Low
3 - Gray 3 - Gray Start Low
4 - Blue 4 - Blue Shut down Low
5 - Pink 5 - Pink Not connected
6 - Yellow 6 - Yellow Power on High
7 - Red 7 - Red Ready High
8 - Green 8 - Green Stop Low
9 - Black 9 - Black Start request Low