User`s manual
SYSTEM CONTROLLER User’s Manual
35
SYSTEM CONTROLLER User’s Manual
34
At the [CONTROLLER SETUP 1 ] menu, press the
button (see p.31).
Press the 1 button to open the Response Setup screen.
Press the 1 button to set the controller RESPONSE
setting to ON. The controller automatically restarts to
apply the change.Press the 2 button to set the
controller RESPONSE setting to OFF. The master
controller display shows the setup screen for the
number of the connected subcontroller.
Press the 1 ~ 4 button to set the number of the desired
sub controller. The controller automatically restarts to
apply the changed settings after entering the number.
- 1: Sets the number of sub-controllers to 4 including
the master controller.
- 2: Sets the number of sub-controllers to 8 including
the master controller.
- 3: Sets the number of sub-controllers to 12 including the master controller.
- 4: Sets the number of sub-controllers to 16 including the master controller.
• Set the maximum number of sub-controllers, to shorten the sub controller data loading time
by making the master controller memorize the number of sub-controllers.
• If Response is set as ON, a maximum of 12 sub-controllers only can be selected.
5. RESPONSE
This menu is for setting RESPONSE function of the camera which is connected Controller.
For information on camera RESPONSE settings (DIP switch settings), refer to the camera manual.
5-3. SPD-1000 DIP Setup
5-2. SPD-3300/3000/2300 DIP Setup
5-1. SPD-3750T/3750/3350 DIP Setup
5-4. SPD-1600 DIP Setup
ON OFF
DIP-SW 1 Not used Always OFF
DIP-SW 2 Reserved Always OFF
DIP-SW 3 RESPONSE Setup HALF DUPLEX FULL DUPLEX
DIP-SW 4 Factory default Always OFF
5-2. SPD-2500 DIP Setup
ON OFF
DIP-SW 1 Not used Always OFF
DIP-SW 2 Reserved Always OFF
DIP-SW 3 RESPONSE Setup HALF DUPLEX FULL DUPLEX
DIP-SW 4 Factory default Always OFF
5-3. SPD-2200 DIP Setup
ON OFF
DIP-SW 1 RESPONSE Setup HALF DUPLEX FULL DUPLEX
DIP-SW 2 Reserved Always OFF
DIP-SW 3
Termination setting
Refer to the camera user manual
DIP-SW 4
[RESP
[RESP
[RESP
5-1. SPD-3300/3000/2300 DIP Setup
ON OFF
DIP-SW 1 RESPONSE Setup HALF DUPLEX FULL DUPLEX
DIP-SW 2
DIP-SW 3
Termination setting Refer to the camera user manual
DIP-SW 4
DIP-SW 5
DIP-SW 6
Communication method
RS-422 RS-485
DIP-SW 7 Factory regulation Always OFF
DIP-SW 8 PC Communication RS-232Communication OFF
[RESP
•
If the camera RESPONSE is set to two-way reception (RESPONSE ON), the controller
RESPONSE menu must be set to ON. If the camera RESPONSE is set to one-way reception
(RESPONSE OFF), the controller RESPONSE menu must be set to OFF.If this is not followed,
the system may have a configuration conflict. For more information on the camera RESPONSE
settings, direct your inquiries to the installation vendor. If the DIP switch for the camera
connected to the controller is set to two-way reception (RESPONSE ON), this menu can be
used to set up the RESPONSE value for the controller and the number of sub-controllers.
Caution
Controller Mode Controller Mode
ENGLISH
SW2- #8 RESPONSE Setup Response
ON OFF
No Response
SW3- #1 RESPONSE Setup Response
ON OFF
No Response
SW2- #6 RESPONSE Setup Response
ON OFF
No Response