Specifications

100
General Specifications:
3700 3880 3900
Chassis Non-ferrous alloy Non-ferrous alloy Non-ferrous alloy
Chassis cover Cold drawn brass, bronze or Cold drawn brass, bronze or Cold drawn brass, bronze or
stainless steel stainless steel stainless steel
Door Types Wood or metal Wood or metal Wood or Metal
Door Thickness 1-3/4" (44.45mm) standard 1-3/4" (44.45mm) standard 1-3/4" (44.45mm) standard
up to 2-1/4" (57.15mm) available up to 2-1/4" (57.15mm) available up to 2-1/4" (57.15mm)
available
Stile 4-1/2" (144.30mm) minimum with See trim page for stile 4-1/2" (144.30mm) minimum
trim, 3-1/2" (88.90mm) minimum dimensions
without trim.
Mounting Supplied with wood and machine Supplied with wood and Supplied with wood and
screws. Available with thru bolts. machine screws. Available. machine screws. Available
with thru bolts with thru bolts.
Handing Handed. Specify LHRB or RHRB Handed. Specify LHRB or RHRB Handed. Specify LHRB
or RHRB.
Dogging Allen type standard. Available Allen type standard. Available Allen type standard. Available
with cylinder dogging (suffix “CD”) with cylinder dogging (suffix CD)
w/ cylinder dogging (suffix CD)
Top/Bottom Bolts Brass N/A N/A
Latchbolt N/A
Stainless steel, 3/4" (19.05mm) throw
Brass, 3/4" (19.05mm) throw
Rail Roll-formed brass, bronze Roll-formed brass, bronze Roll-formed brass, bronze
or stainless steel or stainless steel or stainless steel
Rail Projection 3-1/4" (82.55mm) maximum 3-1/4" (82.55mm) maximum 3-1/4" (82.55mm) maximum
Opening Height 90" (2286.00mm) standard N/A N/A
Fire Exit 4' x 8' single door 4' x 8' single door 4' x 10' single
Hardware-up to: 8' x 8' pairs of doors 8' x 8' pairs of doors with 8' x 10' pairs of doors
S21 mullion. (with 3600-FR)
8' x 8' pairs of doors
(with 3700-FR)
Trim See trim pages 110, 111 See trim pages 110, 111 See trim pages 110, 111
Finishes AL, US3, US4, US10, US10B, US10BL, AL, US3, US4, US10, US10B, US10BL, AL, US3, US4, US10, US10B,
US32, US32D US32, US32D US10BL, US32, US32D
Certification & Compliance:
ANSI/BHMA A156.3, Grade 1
ANSI A117.1 Accessibility Code
Underwriters Laboratories (UL and CUL) listed
for accident hazard (panic) standard.
Fire Exit hardware for hollow metal doors,
UL and CUL listed for 3 hour, A label and lesser
doors, Prefix “F” before part number.
Fire Exit hardware for wood doors, listed up
to 1-1/2 hour, B label doors.
All exit devices comply with life safety code
NFPA 101.
All fire rated devices comply with fire door
and window code NFPA80.
Order Example:
Example: To order 3880 Rim Exit Device with SL Trim.
Specify:
Standard: 38 88 SL 26D F 32D RR xxx
Series Function Outside Trim
(If Applicable)
Outside
Finish
Rail Size
Push Bar
Finish
Handing Options
(If Required)
3000 Series Exit Devices
Premier Product
3700 Surface
Vertical Rod Exit Device
3880
Rim Exit Device
3900
Mortise Exit Device