Specifications
Quintech Electronics and Communications Inc.
SRX Series Switching System Rev. A
3
OUTPUT
C
O
N
T
R
O
L
I
N
C
O
N
T
R
O
L
O
U
T
123456789
10 11 12 13 14 15 16
ELECTRONICS AND COMMUNICATIONS INC.
-5V
+5V
INPUTS
16x1 Switching Module
3.0 INSTALLATION
The SRX is very easy to install. Each module is 1RU (1.75”) in height and is easily installed in
any standard rack, using four screws.
RF Connections
All RF connections are made by connecting source(s) to the input(s) and destination(s) to the
output(s). When connecting, be sure that the pin at the center of the RF connector is properly
inserted into the F connector on the units. A bent pin will not pass the RF signal correctly.
NOTE: All inputs and outputs are DC blocked. You cannot send power through the SRX
to power other devices.
Control Connections
Before powering up the units, make sure all of the control cables are properly installed. All
SRX modules should be daisy-chained together, with the controller unit occupying the first
position in the chain. Connect the CONTROL OUT port of the controller to the CONTROL IN
port of the first 16x1 module in the chain. The CONTROL OUT port of that module connects to
the CONTROL IN port of the next 16x1 module, etc. The last module in the chain will have an
unused 9-pin connector labeled CONTROL OUT.
Note that the maximum control cable length that can exist between SRX modules is 6 feet.