Specifications

Quintech Electronics and Communications Inc. Protocol Version 2.15 20
SRX Series Protocol
DESIGNS AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 2002 QUINTECH INC. ALL RIGHTS RESERVED.
Serial Interface
A new command can be sent to the matrix as soon as a response to the previous command
is received. If a break in communication occurs while a message is being transmitted the
input buffer will automatically clear and no error response will be given.
Serial Parameters:
Baud Rate: 9600
Data Bits: 8
Stop Bits: 1
Parity: None
Protocol: STX/ETX
Flow Control: None. The program sending commands must wait until a response is received
from the matrix controller before sending another command.
SRX “Control In” Serial Pinouts:
RS-232 RS-422/485
1 – GND 1 - GND
2 - TXD 2 - NC
3 – RXD 3 – Non-Inverting Transmit (+)
4 – NC 4 – Non-Inverting Receive (+)
5 – GND 5 - GND
6 – Not Used 6 – Inverting Transmit (-)
7 – NC 7 - NC
8 – NC 8 - NC
9 – Not Used 9 – Inverting Receive (-)
Note on the RS-232 port:
No null modem or crossover cable is needed on the serial port.
Note on RS-485 mode:
RS-485 is compatible with RS-422. RS-485 allows multiple devices on a single shared serial
bus. The SRX unit uses a 4-wire RS-485 interface.