Specifications

Quintech Electronics and Communications Inc.
SRX Series Switching System Rev. A
16
4.4 Serial Port Control
The SRX has a standard DB-9 serial input connector on the back panel. This connector is
shared for both RS-232 and RS-422/485 interfaces. The serial port parameters are fixed at 9600
baud, 8 data bits, no parity, and 1 stop bit (8N1). No NULL MODEM or crossover cable is
required on this port. The command protocol for controlling the switch is provided in
Appendix A.
The RS-232 pin out is as follows: The RS-422/485 pin out is as follows:
1 Not Used 1 NC
2 – TXD (transmit data) 2 – NC
3 – RXD (receive data) 3 – Non-Inverting Transmit
4 Not Used 4 Non-Inverting Transmit
5 – GND (signal ground) 5 – NC
6 Not Used 6 Inverting Transmit
7 Not Used 7 NC
8 Not Used 8 NC
9 Not Used 9 Inverting Receive
1
2
34
5
6
78
9
1 2 3 4 5
6 7 8 9
Male D-9 Connector