Specifications

Quintech Electronics and Communications Inc.
SRX Series Switching System Rev. A
11
4.2.2.1 Serial Configuration
Whenever “Serial” is selected, you will be able to configure both the address of the SRX and
the type of serial interface (RS-232, RS-485, or RS-422).
1. Address 3. Terminate RS485
2. Mode F4=Exit
Address Menu
Address
The Address Screen allows you to set a 2-byte hexadecimal address for the switch. Addresses
can be set from 00 to FF hexadecimal. The unit only responds to commands sent over the serial
bus that contain a matching address. The only exception is the address “FF” which serves as the
“broadcast” address. Any and all units will respond to a command containing FF as the address,
regardless of its current address. For this reason, FF should not normally be used as a unit
address. To change the address, use the up and down scroll arrows until the desired address is
displayed, then press F1 to select the new address. The specified address is used when sending
commands to the control unit from a computer.
Current Address 0 F1=Enter
New Address
np
1A F4=Exit
Address Screen