Specifications
Quintech Electronics and Communications Inc.
SRX Series Switching System Rev. A
9
Model
The model number is included as part of the system’s firmware identification in accordance with
the protocol outlined in Appendix A. The control system is not affected by the model number.
System expansion requires no change of the model number.
Model: 2150 F1=Enter
F4=Exit
Typical Model Number Screen
Module Size
Configuring the SRR module size involves specifying the number of inputs per SRX
(option 1) and the number of input rows/SRO (option 2).
1. SRR Module Size
2. SRO Module Size F4=Exit
Module Size Menu
The SRR module size must be set to the number of inputs on each SRX module. The SRO
module size must be set to the number of inputs on the MCP. The factory default is 8. The
default is 16 for a system with 16x1 expansion modules. If the MCP is used as a standalone
switch with no expansion modules, the factory default is 1.