Instructions / Assembly
Page 9
TROUBLESHOOTING
Problem Cause Solution
Igniter pin and burner are wet Dry off with a soft cloth
Igniter battery is incorrectly inserted Check which direction the battery is 
inserted
Igniter pin is broken
Contact us. for a replacement part
Electrode wire is loose or disconnected Reconnect wire to the igniter box located 
inside the table behind the igniter box
Electrode wire is shorting between valve 
and igniter pin
No gas flow Check that the gas tank isn’t empty
Regulator isn’t connected securely to the 
tank
Tighten regulator connection to the gas 
tank
Gas flow is obstructed Check all hoses for kinks and bends
Burner ports are clogged Turn all gas flow connections off. Insert 
an opened paperclip (or similar item) into 
each of the burner ports to clear them 
out.
Flame is obstructed at burner ports
Regulator hose is kinked Straighten hose of all bends or kinks
No gas flow Check that the gas tank isn’t empty
Excess flow safety valve has been 
activated
Turn the control knob to the ‘off’ position. 
Close the tank valve and disconnect 
propane gas tank. Turn the control 
knob to ‘high’; wait 1 minute. Turn the 
control knob back to the ‘off’ position. 
Reconnect propane gas tank. Light the 
fire unit as indicated in the ‘To Light’ 
section of this manual.
High or gusting winds Increase flame to ‘high’
No gas flow Check that the gas tank isn’t empty
Excess flow safety valve has been 
activated
See ‘sudden drop in gas flow’ above
Heating unit won’t light
Burner won’t light 
while using a match
Heating unit emits a lot 
of black smoke
Sudden drop in gas 
flow
Flame blows out easily
Contact us. for a replacement part
Check that all burner ports are free of 
any small lava rocks/pumice stones/
LavaGlass pieces