Goodman AVPTC Spec Sheet ComfortBridge

2 www.goodmanmfg.com SS-GAVPTC
SS-GAVPTC www.goodmanmfg.com 3
Product Specifications
AVPTC
25B14B*
AVPTC
29B14B*
AVPTC
31C14B*
AVPTC
33C14B*
AVPTC
35B14B*
AVPTC
37B14B*
AVPTC
37C14B*
AVPTC
37D14B*
Nominal Ratings
Cooling (BTU/h) 24,000 30,000 30,000 24,000 28,000 36,000 36,000 36,000
CFM (High range) 1085/650 1085/610 1315/870 1090/685 1020/685 1085/610 1315/870 1375/865
Blower
Diameter 9½" 9½" 10⅝" 10⅝" 9½" 9½" 10⅝" 10⅝"
Width 6" 6" 8" 8" 6" 6" 8" 10⅝"
Coil Drain Connecon FPT ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Service Valve
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon ¾" ⅞" ⅞" ⅞" ¾" ⅞" ⅞" ⅞"
Electrical Data
Voltage 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240
Min Circuit Ampacity 4.9/4.9 6.5/6.5 6.5/6.5 4.9/4.9 4.9/4.9 6.5/6.5 6.5/6.5 6.5/6.5
Max. Overcurrent Device (amps) 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15
Minimum VAC 197 197 197 197 197 197 197 197
Maximum VAC 253 253 253 253 253 253 253 253
Blower Motor
FLA 3.9 5.2 5.2 3.9 3.9 5.2 5.2 5.2
HP ½ ¾ ¾ ½ ½ ¾ ¾ ¾
Ship Weight (lbs) 116 129 144 118 116 129 144 155
Note: Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protecon (MOP) for blower without supplemental heat installed.
Refer to unit nameplate and/or Heat Kit Data for specicaon with approved accessory heaters installed
AVPTC
39C14B*
AVPTC
49C14B*
AVPTC
49D14B*
AVPTC
59C14B*
AVPTC
59D14B*
AVPTC
61D14B*
Nominal Ratings
Cooling (BTU/h) 36,000 48,000 42,000 48,000 48,000 60,000
CFM (High range) 1315/965
1420/1040 1530/1195 1595/875 1990/1445 2025/1630
Blower
Diameter 10⅝" 10⅝" 10⅝" 10⅝" 11¹⁵₁₆" 11¹⁵₁₆"
Width 8" 8" 10⅝" 8" 10⅝" 10⅝"
Coil Drain Connecon FPT ¾"
¾" ¾" ¾" ¾" ¾"
Service Valve
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon ⅞"
⅞" ⅞" ⅞" ⅞" ⅞"
Electrical Data
Voltage 208/240 208/240 208/240 208/240 208/240 208/240
Min Circuit Ampacity 6.5/6.5 6.5/6.5 6.5/6.5 8.6/8.6 8.6/8.6 8.6/8.6
Max. Overcurrent Device (amps) 15/15 15/15 15/15 15/15 15/15 15/15
Minimum VAC 197 197 197 197 197 197
Maximum VAC 253
253 253 253 253 253
Blower Motor
FLA 5.2 5.2 5.2 6.9 6.9 6.9
HP ¾
¾ ¾ 1 1 1
Ship Weight (lbs) 118 125 167 144 155 167
Note: Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protec-
on (MOP) for blower without supplemental heat installed.
Refer to unit nameplate and/or Heat Kit Data for specicaon with approved accessory heaters installed