Technical information
Table Of Contents
- DCS_Direct_Jet_1024UVHS_Maintenance_Troubleshooting_Guide_1.2
- 0TSAFETY AND PRECAUTIONS
- MAINTENANCE and CLEANING
- Daily Maintenance and Cleaning
- Weekly Maintenance and Cleaning
- Monthly or Periodic Maintenance
- Correcting a Bad Nozzle Check Condition
- Clear a Clogged Nozzle for the Print Head
- The Capping Station
- X & Y "0" Calibration Adjustment
- Print Head and Lamp Height Check
- Adjusting the head height
- Replacing a Direct Jet Print Head
- TROUBLE SHOOTING
- Error Conditions
- Hardware Troubleshooting Guide
- Print quality and Ink Supply Problems
- PRINTING - INFO SHEET AND FAQs
- DCS_Direct_Jet_UV_Printer_Maintenance_Log_REVB021413

Troubleshooting
Go to table of contents
DCS_Direct_Jet_1024UVHS_Maintenance_Troubleshooting_Guide_1.2.docx 31 | Page
Symptoms Check Replace
Pressing Control Panel
buttons: Left Arrow, Right
Arrow, or Print Home
doesn't move the media
table.
Check and verify print home (table control lock)
has not been pressed (See Print Home
Description). Press .
Check and reseat cable connected to CN3 on the
YACB board.
Check and reseat cable connected to CN11 on
the YACB board.
Check F1, 42 VDC fuse on the YACB board.
Check F2, 5 VDC fuse on the YACB board.
Check the Y-axis motor and gear train.
Replace 42 VDC 2 Amp
Fuse.
Replace 5 VDC 1 Amp.
Fuse.
Replace YACB Board.
Replace Y-axis motor.
Replace Printer Power
Supply
Pressing Control Panel
buttons: Up Arrow and
Down Arrow, doesn't move
the print engine elevator
up or down.
Check and reseat cable connected to CN1 on the
EIB board and the Z-axis motor.
Check 24VDC fuse on the EIB board.
Check Z-axis Limit sensors, motor and gear train.
Replace 24 VDC 2 Amp.
Fuse.
Replace EIB board.
Replace Z-axis motor.
Replace Z-axis Limit
sensor.
Replace Printer Power
Supply