Maintenance
Go to table of contents
DCS_Direct_Jet_1024UVHS_Maintenance_Troubleshooting_Guide_1.2.docx 26 | Page
UV Lamp Height Adjustment
Always check the head height
before the UV lamp height!
If you have performed and are satisfied with the
head height adjustment, place two shims on the
media table in front of the UV lamp.
Press and hold then use the arrow keys to move the media table so the shims
are under the lamp. The lamp should be only slightly above the shims (enough so that a
piece of copier paper can fit).
If the lamp is not at the right height, hold the
lamp and use the hex tools to first loosen the set
screw and then the lamp screw. Do not let the
lamp slide on its own. Move the lamp so that it is
at the proper height then tighten the lamp screw
and then the set screw.
Lamp screw
Set screw