Maintenance
Go to table of contents
DCS_Direct_Jet_1024UVHS_Maintenance_Troubleshooting_Guide_1.2.docx 24 | Page
Check head height
Remove the tool. Press the down arrow button and hold it until the elevator stops, then
release it. This sets the print head height.
Using and the arrow buttons once again, move the table until it is under the print
head.
Slide the DCS Head Height Gauge between the Print Head and the Media Table. It should fit
all the way under the head, with very little gap (just enough to slide a piece of paper in
between. Move the head to another point on the axis and check again. Check in several
places. If there is any significant difference at any of these points, contact DCS Tech
Support for adjustment information. If the head height needs adjustment, go to page 25.
Otherwise, if the head is at the proper height, stack the two guides and check the height of
the UV lamp using the same method. If the lamp height needs adjustment, go to page 26.