Technical information
Table Of Contents
- DCS_Direct_Jet_1024UVHS_Maintenance_Troubleshooting_Guide_1.2
- 0TSAFETY AND PRECAUTIONS
- MAINTENANCE and CLEANING
- Daily Maintenance and Cleaning
- Weekly Maintenance and Cleaning
- Monthly or Periodic Maintenance
- Correcting a Bad Nozzle Check Condition
- Clear a Clogged Nozzle for the Print Head
- The Capping Station
- X & Y "0" Calibration Adjustment
- Print Head and Lamp Height Check
- Adjusting the head height
- Replacing a Direct Jet Print Head
- TROUBLE SHOOTING
- Error Conditions
- Hardware Troubleshooting Guide
- Print quality and Ink Supply Problems
- PRINTING - INFO SHEET AND FAQs
- DCS_Direct_Jet_UV_Printer_Maintenance_Log_REVB021413

Maintenance
Go to table of contents
DCS_Direct_Jet_1024UVHS_Maintenance_Troubleshooting_Guide_1.2.docx 13 | Page
13. Clean the print head encoder strip for the X-axis. Using an IPA wipe, clean the
encoder strip.
Both sides of the encoder strip used by the print head
should be wiped gently with an IPA wipe (included in
the cleaning kit) in order to remove any debris that may
have fallen on to it during the lubrication process or from
ink residue.
14. Clean the wiper blade. Clean the wiper in the capping station to avoid streaking in your
finished images and/or if drops of ink on the bottom of the head are not being wiped off
after a cleaning cycle.
Monthly or Periodic Maintenance
15. Inspect intake fan filter on UV lamp. Lift the cover. Press to unlock the print
head carriage. When it has stopped moving, manually move it to the far left of the shaft.
Inspect the fan filter.
Old filter
New filter
Change the intake fan filter
1. Press to unlock the print head carriage. When it has stopped moving, manually
move it to the far left of the shaft. Turn off main power.
2. Remove the 4 screws from the filter
retainer.