Technical information
Maintenance
Go to table of contents
DCS_Direct_Jet_1024UV_1014UV_Maintenance_Troubleshooting_Guide_2.1.docx 17 | Page
Replace the Capping Station
Replace a Capping Station if:
a. The gaskets no longer form a tight seal around the print heads, and the cleaning cycle does
not perform properly.
b. Some type of physical damage has occurred to the unit.
c. There is an electrical failure of the pump motor.
d. It is more than 90 days old.
Long magnetized Philips head screwdriver
Tools Required
Needle-nose pliers
Approximately 20 minutes
Time Required
The Capping Station is mounted to the printer with 5 Philips head screws (4 hold it in place + 1 for
the orange ground wire). There is also 1 small electrical connector that needs to be disconnected.
1. Remove the acrylic front cover. Remove the four thumb screws. With assistance, lift the cover
straight up and off of the printer.
2. Press the up arrow button until the print engine is at its maximum height. Press . Turn
off main power. DO NOT PRESS .
3. Remove the 4 Philips head screws.