Technical data

10
Dimensions
A B
C
D
VHR1404/
VHR1405R
0
0.2
0.4
0.6
0.8
1
1.2
0.00
50.00
100.00
150.00
200.00
250.00
300.00
40.000.00 80.00 120.00 160.00
Airflow (cfm)
Airflow (L/s)
Static Pressure (in WC)
Static Pressure (Pa)
200.00 240.00
19.000.00 38.00 57.00 76.00 94.00 114.00
VHR2004
VHR2005R
Optional recirculation
duct collar (provided)
with VHR 1405R
& VHR 2005R only
Airflow
PHRV 140, PHRVR 155 & PHRVR 205 Series HRV
Model A B C D
PHRV 140 23
3
/4" (604mm) 17
1
/4" (438mm) 16
1
/4" (413mm) 2
1
/4" (56mm)
PHRVR 155 23
3
/4" (604mm) 17
1
/4" (438mm) 16
1
/4" (413mm) 2
1
/4" (56mm)
PHRVR 205 28" (711mm) 17
1
/4" (438mm) 20
1
/2" (521mm) 2
1
/4" (56mm)
Fan Performance
Performance Data
Model
PHRV 140 81 % 79 %
PHRVR 155 81 % 79 %
PHRVR 205 71 % 76 %
Apparent Sensible
Effectiveness at
32ºF (0ºC)
Apparent Sensible
Effectiveness at
-13ºF (-25ºC)
AIRFLOW CAP. cfm (L/s) @ 0.4 on High Speed
* All collars on the
Series have a
diameter of 6".
Power
• Volts 120VAC
• Amperage 0.8 - 1.6 A
• Phase Single
PHRV 140 &
PHRVR 155
PHRVR 205
Optional recirculation
duct collar (provided)
with PHRVR 155 &
PHRVR 205