Installation Guide

4
°C °F L/s CFM
Heating 0 32 40 85 73 66 79 -0.01
0 32 47 100 108 63 79 0.01
-25 -13 42 89 107 60 72 0.02
Dimensions & AIRFLOW
- All units feature three foot plug-in power cord with 3-prong plug.
Pa in wg L/s cfm L/s cfm L/s cfm
50 0.2 83 176 84 178 84 178
100 0.4 73 155 74 157 74 157
150 0.6 61 129 62 131 61 131
200 0.8 51 108 52 110 52 110
250 1.0 41 87 41 87 41 87
EXT. STATIC
PRESSURE
NET SUPPLY
AIR FLOW
GROSS AIR FLOW
SUPPLY EXHAUST
Ventilation Performance
Energy Performance
Exhaust Air
To Outside
Exhaust Air
From Building
Fresh Air
From Outside
Fresh Air
To Inside
Access
Door
6" oval
(152 mm)
Electrostatic
Filters
Electrical
Box
Aluminum
Core
EBM
Motor
POWER
CONSUMED
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
1
LATENT
RECOVERY/MOISTURE
TRANSFER
Specifications and Ratings
• Model: PHRVR150
• Total assembled weight: 45 lbs (20Kg)
• Cabinet: 24 ga, steel with powder coat finish
Motors: ebm motor with backward curved
blades
• Filters: 2 washable electrostatic filters
8.5" (216mm) x 15" (380mm) x 0.125" (3mm)
• Insulated with 1" (25mm) high density
polystyrene foam to prevent condensation
• Core: Aluminum
9" (229mm) x 9" (229mm) x 15" (380mm)
• Supply & exhaust ducts: 6" oval (150 mm)
• Mounting: Suspended by chains & hooks
•Electrical requirements::
Volts Frequency Amps Watts
120V 60Hz 1.2A 170W
3' plug-in power cord w/ 3-prong plug
SUPPLY
TEMPERATURE
NET
AIRFLOW
23 ¾"
(604 mm)
16¼"
(413 mm)
2
3
/
16
"
(56 mm)
17
3
/
16
"
(438 mm)
1
Not an HVI certied value
Airow (L/s)
Airow (cfm)
Static Pressure (in H
2
O)
Static Pressure (Pa)
Reduced Speed
Normal Speed
2
1
0 50 100 150 200
0 24 47 71 94
0.2
0.4
0.6
0.8
1.0
50
100
150
200
1.0
1
2