Installation Guide

15
AUXILIARY CONTROL – These controls can be paired
RTS20*
20- minute timer with LED light
Boosts system to high speed with the touch of a button
Up to 5 can be used in one system
Use in bathroom, kitchen, laundry room
RTS5
20/40/60 minute timer with LED light
Boosts system to high speed with the touch of a button
Up to 5 can be used in one system
Use in bathroom, kitchen, laundry room
Dehumidistat Rotary dial Dehumidistat
Multiple units can be used
We recommend setting the relative humidity above 80% during the summer
Low Voltage Control Systems
* Please see instruction manuals for individual controls for proper wiring and set up of control systems.
CENTRAL CONTROLS
These control options can only be used individually
CONTROLS FEATURES CONNECT TO
DIR-TS Our most complete, yet easy to use control system
Sleek design with backlight touchscreen LCD
ECO mode selects the best operating mode and speed for the season,
minimizing energy use associated with ventilation
Set preferred indoor relative humidity range and ventilation mode for day
and night conditions
No battery to replace, all programmed settings are retained during power
outage
Maintenance reminder indicator
Error code messages reduce troubleshooting time
DIR-DG
MODE button provides 3 modes of operations: Ventilation , Recircula-
tion and Standby
User selected fan speed: Reduced, Medium, Normal and 20 minutes
per hour
AUTO setting allows the homeowner to deactivate the dehumidistat
When the humidity exceeds the desired setpoint, the ventilation sys-
tem operates at Normal speed.
Once the desired humidity level is achieved, your ventilation system
resumes to its previous mode of operation
EDF1/EDF1R Press button once for continuous Reduced speed
Press button twice and the unit will cycle 20 minutes ON/ 40 minutes
OFF and repeat
EDF1 – Press button a third time and the system will run continuously
on HIGH speed
EDF1R –Press button a third time and the system will run recirculation
on HIGH speed
1. Ensure that unit is not
plugged when connecting
the control
2. Recirculation mode is only
available with the “R” sufx
at the end of the model
number.
The wiring connectors
can be removed for
easier connection.
*Maintain polarity
between control
and HRV
(+ + ; - -)
W
W
W
W
W
W
+T
-T
D
D
+T
-T