Installation Guide

11
HRV INSTALLATION
LOCATION
The HRV must be located in a conditioned space where it will be possible to conveniently service the unit. Typically
the HRV would be located in the mechanical room or an area close to the outside wall where the weatherhoods will
be mounted. If a basement area is not convenient or does not exist, a utility room may be used.
Attic installations are not normally recommended due to:
The complexity of the installation
Freezing conditions in the attic
Difficulty of access for service and cleaning
No drain access
Connecting appliances to the HRV is not recommended. These include:
Clothes dryer
Range top
Stovetop fan
Central vacuum system
Bathroom exhaust fans unless they are specifically designed for this purpose
These appliances may cause lint, dust or grease to collect in the HRV, damaging the unit.
MOUNTING – WALL MOUNT
For PHRVR104 ES, PHRVR100 ES only
1. Attach bracket to wall
2. Lift unit & slide nuts into slots on bracket
3. Tighten screws to secure unit to bracket
4. Insert the safety screws & place wall bumpers to level off the unit.
* Optional chain hanging kit available.
Safety screws
(included)
Place bumpers on
back of unit if not
already installed
(included)
16” (406mm)
Have a nearby power supply
(120 volts, 60Hz)
Choose a location which
allows the possibility
of mounting the unit to
supporting beams.
The unit should be level
in order to allow proper
condensate drainage
To minimize noise, do not
install unit in living area
Ensure proper drainage
Connecting any of these types of
appliances to the HRV will void your
warranty.