Datasheet

1
) Leads kept at ambient temperature at a distance of 3 mm from case
Anschlußdrähte in 3 mm Abstand von Gehäuse auf Umgebungstemperatur gehalten
409
DA811A/K … DA8110A/K (1.2 W)
Max. power dissipation – Verlustleistung T
A
= 25°C P
tot
1.2 W
1
)
Operating junction temperature – Sperrschichttemperatur T
j
– 50…+150°C
Storage temperature – Lagerungstemperatur T
S
– 50…+150°C
Characteristics Kennwerte
Forward voltage T
j
= 25°C I
F
= 1 A V
F
< 1.1 V
Durchlaßspannung
Leakage current T
j
= 25°C V
R
= V
RRM
I
R
< 10 µA
Sperrstrom T
j
=100°C V
R
= V
RRM
I
R
< 90 µA
Thermal resistance junction to ambient air R
thA
< 85 K/W
1
)
Wärmewiderstand Sperrschicht – umgebende Luft