User guide

ATS137
SINGLE HALL EFFECT SWITCH
ATS137 Rev. 10 4 of 12 FEBRUARY 2010
DS31045
www.diodes.com © Diodes Incorporated
Recommended Operating Conditions
Symbol Characteristic Conditions Min Max Unit
V
CC
Supply Voltage Operating 3.5 20 V
T
A
Operating Ambient Temperature Operating -20 85
°C
Electrical Characteristics (T
A
= + 25°C)
Symbol Characteristic Test Conditions Min Typ. Max Unit
V
ce
(
SAT
)
Output Saturation Voltage V
CC
= 14V, I
CC
= 20mA - 300 700 mV
I
cex
Output Leakage Current V
ce
= 14V, V
CC
= 14V -
<0.1
10 uA
I
CC
Supply Current V
CC
=20V, Output Open - 5 10 mA
tr Output Rise Time
V
CC
= 14V, RL = 820Ω,
CL = 20pF
- 0.3 1.5 us
tf Output Falling Time
V
CC
= 14V, RL = 820Ω,
CL = 20pF
- 0.3 1.5 us
CL
14V
DO
RL = 820 Ohm
CL = 20 pF
RL
Test Circuit
Test Circuit