User guide
AP131
300mA LOW DROPOUT LINEAR REGULATOR WITH
SHUTDOWN
AP131 Rev. 7 3 of 7 FEBRUARY 2009
www.diodes.com © Diodes Incorporated
Absolute Maximum Ratings
Symbol Parameter Rating Unit
V
CC
Input Voltage +6 V
T
OP
Operating Junction Temperature Range -40 to +125 ºC
T
ST
Storage Temperature Range -65 to +150 ºC
P
D
Power Dissipation, P
D
@ T
A
= 25ºC SOT25 250 mW
Recommended Operating Conditions
Symbol Parameter Min Max Unit
V
IN
Input Voltage 2.7 5.5 V
I
OUT
Output Current 0 300 mA
T
A
Operating Ambient Temperature -40 85
°C