Manual
2 OF 3
INSTALLATION SHEET
Independent Setup: (Primary xture operang independently or commanding addional xtures)
1. Link each wall washer together with the aached male and female 3-pin M14 conneons (maximum run: 10 xtures). Power up each wall washer
by inserng the AC cord into a standard 120VAC electrical receptacle (Fig. 2a).
2. Once powered, the on-board control pad of each wall washer will automacally set to the Address Menu. Choose the preferred xture to operate
as the master controller (this can be any xture in the series) and set the code in the Address Menu of the master xture to the default address
‘001’. Do so by seng Fields 1 & 2 to ‘0’ and Field 3 to ‘1’.
3. In the master wall washer Funcon (P) Menu (Fig. 2a), set the desired command for all master & slave xtures to perform in Fields 2 & 3. Once
selected, wait 10 seconds for the selected eld to stop ashing and the selected command will be set
4. To sync the slave washers to the master washer, set the code in the Address Menu of each slave xture to any number other than ‘001’ (Fig. 2b). It
is recommended to set each slave with an individual code (e.g. ‘002’, ‘003’, ‘004’ etc.). The Funcon (P) Menu is not required to operate slave wall
washers.
WET LOCATION WALL WASHERS
A B
Address Menu
Fig. 1a
Field 1 Field 2 Field 3
A B
Field 1 Field 2 Field 3
Function (P) Menu
Fig. 1b
P 6
Master Wall Washer Slave Wall Washer
Fig. 2b
Fig. 2a
A B
002
A B
P63
A B
0 0 1
DMX Controller Setup: (One or more wall washers commanded by a DMX controller)
Please note that all DMX control systems operate dierently and may require addional technical knowledge of the DMX controller and equipment to
operate the wall washers eecvely. It is recommended that only experienced technicians install DMX control systems.
1. Aach the included XLR-3 adapter cable between the DMX controller and wall washer 3-pin M14 connecon (Fig. 3)
(not all DMX controllers have XLR-3 connecons).
2. Link each addional wall washer together with the aached male and female mini 3-pin cables (maximum run: 10 xtures).
3. Power each xture by inserng the AC cord into a standard 120VAC electrical receptacle.
4. Once powered, the on-board control pad of each wall washer will automacally set to the Address Menu. To eecvely command the xtures
with the DMX control, match the value of each addressing eld with the 3-channel address code commanded from the DMX controller.
DMX Controller
with 3-pin XLR Plugs
Fig. 3
Operaon Overview (connued)
Each wall washer has its own on-board control pad and 3-digit display, operated by two menu buon
controls – ‘A’ and ‘B’. Buon ‘A’ cycles through the 3-digit display and switches the display from the
Address Menu (Fig. 1a) to the Funcon (P) Menu (Fig. 1b). Pressing Buon ‘B’ connually changes the
desired value of each eld.
At startup, the wall washer will always be set in the Address Menu. To switch to the Funcon (P) Menu
(Fig. 1b), press Buon ‘A’ once and Field 3 will begin to ash. Press Buon ‘A’ three mes to be directed
to the Funcon (P) Menu. Once in the Funcon (P) Menu, press Buon ‘A’ two mes to switch back to
the Address Menu.