Manual

2 OF 3
INSTALLATION SHEET
Independent Setup: (Primary xture operang independently or commanding addional xtures)
1. Link each wall washer together with the aached male and female 3-pin M14 conneons (maximum run: 10 xtures). Power up each wall washer
by inserng the AC cord into a standard 120VAC electrical receptacle (Fig. 2a).
2. Once powered, the on-board control pad of each wall washer will automacally set to the Address Menu. Choose the preferred xture to operate
as the master controller (this can be any xture in the series) and set the code in the Address Menu of the master xture to the default address
‘001’. Do so by seng Fields 1 & 2 to ‘0’ and Field 3 to ‘1’.
3. In the master wall washer Funcon (P) Menu (Fig. 2a), set the desired command for all master & slave xtures to perform in Fields 2 & 3. Once
selected, wait 10 seconds for the selected eld to stop ashing and the selected command will be set
4. To sync the slave washers to the master washer, set the code in the Address Menu of each slave xture to any number other than ‘001’ (Fig. 2b). It
is recommended to set each slave with an individual code (e.g. ‘002’, ‘003’, ‘004’ etc.). The Funcon (P) Menu is not required to operate slave wall
washers.
WET LOCATION WALL WASHERS
A B
Address Menu
Fig. 1a
Field 1 Field 2 Field 3
A B
Field 1 Field 2 Field 3
Function (P) Menu
Fig. 1b
P 6
Master Wall Washer Slave Wall Washer
Fig. 2b
Fig. 2a
A B
002
A B
P63
A B
0 0 1
DMX Controller Setup: (One or more wall washers commanded by a DMX controller)
Please note that all DMX control systems operate dierently and may require addional technical knowledge of the DMX controller and equipment to
operate the wall washers eecvely. It is recommended that only experienced technicians install DMX control systems.
1. Aach the included XLR-3 adapter cable between the DMX controller and wall washer 3-pin M14 connecon (Fig. 3)
(not all DMX controllers have XLR-3 connecons).
2. Link each addional wall washer together with the aached male and female mini 3-pin cables (maximum run: 10 xtures).
3. Power each xture by inserng the AC cord into a standard 120VAC electrical receptacle.
4. Once powered, the on-board control pad of each wall washer will automacally set to the Address Menu. To eecvely command the xtures
with the DMX control, match the value of each addressing eld with the 3-channel address code commanded from the DMX controller.
DMX Controller
with 3-pin XLR Plugs
Fig. 3
Operaon Overview (connued)
Each wall washer has its own on-board control pad and 3-digit display, operated by two menu buon
controls – ‘A’ and ‘B’. Buon ‘A’ cycles through the 3-digit display and switches the display from the
Address Menu (Fig. 1a) to the Funcon (P) Menu (Fig. 1b). Pressing Buon ‘B’ connually changes the
desired value of each eld.
At startup, the wall washer will always be set in the Address Menu. To switch to the Funcon (P) Menu
(Fig. 1b), press Buon ‘A’ once and Field 3 will begin to ash. Press Buon ‘A’ three mes to be directed
to the Funcon (P) Menu. Once in the Funcon (P) Menu, press Buon ‘A’ two mes to switch back to
the Address Menu.