Before you begin, read all warnings and installaon instrucons thoroughly.
Waterproong XLR-3 Connecons
When installing outdoors or in a wet locaon, ensure water-resistant end caps
are connected to all wet locaon 3-pin M14 connecons. If aaching XLR-3
DMX adapter cables seal all XLR-3 connecons with 1.25” wide heat shrink and
nish waterproof tape (not included). Do not use liquid sealants of any kind.
Use a heat gun with a minimum heang temperature of 212° F (100°C) when
shrinking tube.
Operaon Overview
Wall Washers can be operated in two ways:
1) Independently (One or more xtures): Primary xture operang independently or commanding addional xtures.
2) With a DMX Controller: One or more wall washers commanded by a DMX controller.
Safety & Warnings
• Turn power OFF at main breaker before servicing or installing this product.
• This product is intended to be installed and serviced by a qualied, licensed electrician.
• Install in accordance with the Naonal Electric Code, and local regulaons.
• Install in a well-venlated, combuson-free environment.
• Do not disassemble or modify this product. Doing so will void your warranty.
• This xture is not compable with any tradional dimming controls. Wall washers can only be controlled/dimmed with the on-board interface or with an external DMX
controller. Please contact customer service for addional informaon.
• Ensure all adjusng screws on mounng brackets and xtures are properly secured prior to permanent installaon.
• When mounng to walls and ceilings, use applicable lag bolts and consider the strength of these surfaces versus the weight of the xture.
• When installing outdoors or in a wet locaon, ensure water-resistant end caps are connected to all exposed wet locaon 3-pin M14 connecons. If aaching XLR-3
adapter cables seal all XLR-3 DMX connecons with 1.25” wide heat shrink and nish with waterproof tape (not included). Do not use liquid sealants of any kind.
• This xture is IP65 rated. Aached wet-locaon 3-pin M14 connecons are IP67 rated.
• It is recommended to power this xture with a GFCI protected circuit.
• This xture is only UL Listed for connecon with a 120VAC, 15- or 20-ampere branch circuit.
• This xture is not to be used in or around chlorinated, treated or salt water due to the corrosive and degrading qualies of chlorine, saline, and other chemicals on the
xture components. Keep at least 16 feet away from pools and spas.
• This xture is rated for use in an environment where the ambient operang temperature is -4° ~ 104° F (-20° ~ 40° C).
WET LOCATION WALL WASHERS
SPHERE-STAR™ Wall Washer
1/2” mounng holes
SPLASHLIGHT™ Wall Washer
3/8” mounng holes
BROADWAVE™ Wall Washer
3/8” mounng holes
212º F (100º C)
Heat the shrink tube evenly
Finish with Waterproof Tape
Step 1. Step 2.
Mounng
Ensure xture is properly mounted and all adjusng screws are properly secured
prior to permanent installaon. All xtures must be individually powered by 120VAC.