Manual

1 OF 3
INSTALLATION SHEET
Before you begin, read all warnings and installaon instrucons thoroughly.
Waterproong XLR-3 Connecons
When installing outdoors or in a wet locaon, ensure water-resistant end caps
are connected to all wet locaon 3-pin M14 connecons. If aaching XLR-3
DMX adapter cables seal all XLR-3 connecons with 1.25” wide heat shrink and
nish waterproof tape (not included). Do not use liquid sealants of any kind.
Use a heat gun with a minimum heang temperature of 212° F (100°C) when
shrinking tube.
Operaon Overview
Wall Washers can be operated in two ways:
1) Independently (One or more xtures): Primary xture operang independently or commanding addional xtures.
2) With a DMX Controller: One or more wall washers commanded by a DMX controller.
Safety & Warnings
Turn power OFF at main breaker before servicing or installing this product.
This product is intended to be installed and serviced by a qualied, licensed electrician.
Install in accordance with the Naonal Electric Code, and local regulaons.
Install in a well-venlated, combuson-free environment.
Do not disassemble or modify this product. Doing so will void your warranty.
This xture is not compable with any tradional dimming controls. Wall washers can only be controlled/dimmed with the on-board interface or with an external DMX
controller. Please contact customer service for addional informaon.
Ensure all adjusng screws on mounng brackets and xtures are properly secured prior to permanent installaon.
When mounng to walls and ceilings, use applicable lag bolts and consider the strength of these surfaces versus the weight of the xture.
When installing outdoors or in a wet locaon, ensure water-resistant end caps are connected to all exposed wet locaon 3-pin M14 connecons. If aaching XLR-3
adapter cables seal all XLR-3 DMX connecons with 1.25” wide heat shrink and nish with waterproof tape (not included). Do not use liquid sealants of any kind.
This xture is IP65 rated. Aached wet-locaon 3-pin M14 connecons are IP67 rated.
It is recommended to power this xture with a GFCI protected circuit.
This xture is only UL Listed for connecon with a 120VAC, 15- or 20-ampere branch circuit.
This xture is not to be used in or around chlorinated, treated or salt water due to the corrosive and degrading qualies of chlorine, saline, and other chemicals on the
xture components. Keep at least 16 feet away from pools and spas.
This xture is rated for use in an environment where the ambient operang temperature is -4° ~ 104° F (-20° ~ 40° C).
WET LOCATION WALL WASHERS
SPHERE-STAR™ Wall Washer
1/2” mounng holes
SPLASHLIGHT™ Wall Washer
3/8” mounng holes
BROADWAVE™ Wall Washer
3/8” mounng holes
212º F (100º C)
Heat the shrink tube evenly
Finish with Waterproof Tape
Step 1. Step 2.
Mounng
Ensure xture is properly mounted and all adjusng screws are properly secured
prior to permanent installaon. All xtures must be individually powered by 120VAC.

Summary of content (3 pages)