User guide
Page 3 of 3
If dimming, please ensure a compable MLV dimmer switch and dimmable LED xture is installed. Incompable dimmer switches and/or xtures are
the most common triggers for faulty installaons.
• Lights are ickering: An incompable dimmer switch or defecve driver may produce excess strobing/ickering. Ensure a compable dimmer is
installed. See dimmer switch specs for minimum load requirements. If excess strobing/ickering is sll apparent, please contact technical support.
• Reset breaker trips repeatedly: Ensure each secondary tap is not overloaded more than 50W, and the total waage does not exceed 300W. Ensure
there is not a short circuit occurring. If the breaker connues to trip aer reset then contact technical support as the driver may be defecve.
• Excess voltage drop: Ensure applicable AWG wire is installed between driver and xture. Addionally, an MLV dimmer switch will trim voltage down,
causing an output less than 12VDC. Performance will not be aected if the xture is receiving ≥ 10.5VDC. Use the Orange Boost Tap (see ‘Boost Tap’)
as an oponal voltage boost in place of the Black (Line) wire if the xture is receiving noceable light degradaon. Cap the exisng hot wire not in
use.
Troubleshoong
For addional quesons/concerns please contact technical support. We are more than happy to assist you with any technical dicules or concerns.
12V 300W CLASS 2 MAGNETIC DIMMABLE DRIVER
INSTALLATION GUIDE
V2.1