DWG2000-1G User Manual v1.0 Dinstar Technologies Co., Ltd. Address: Floor 6, Guoxing Building, Changxing Road, Nanshan District, Shenzhen, China Postal Code: 518057 Telephone: +86 755 2645 6664 Fax: +86 755 2645 6659 Emails: sales@dinstar.com, support@dinstar.com Website: www.dinstar.com www.dinstar.cn VoIPon www.voipon.co.uk sales@voipon.co.
DWG2000-1G User Manual Revision Records Document version 1.0 Firmware version 9.50.41 Revised by Technical Support Department Date 2011/9/8 Changes The first version _______________________________________________________________________________ Dinstar Technologies Co., Ltd. 1 VoIPon www.voipon.co.uk sales@voipon.co.
DWG2000-1G User Manual Table of Contents 1. Equipment Introduction ................................................................................................................. 4 1.1 Introduction ......................................................................................................................... 4 1.2 Scenario of Applications of Products .................................................................................. 4 1.3 Product Appearance ......................................
DWG2000-1G User Manual 4.6 Mobile Configuration ........................................................................................................ 21 4.6.1 Basic Configuration ................................................................................................ 21 4.6.3 SIM/UIM Card Lock ............................................................................................... 23 4.6.4 PIN Management .....................................................................................
DWG2000-1G User Manual 1. Equipment Introduction This chapter mainly introduces functions and structures of DWG2000-1G. 1.1 Introduction DWG2000-1G is full functions VoIP gateway based on IP and GSM wireless network, which provides a flexible network configuration, powerful features, and good voice quality. It works for carrier grade, enterprise, SOHO, residential users for cost-effective solution. 1.2 Scenario of Applications of Products DWG2000-1G provides access of GSM network.
DWG2000-1G User Manual 1.3 Product Appearance The appearance of DWG2000-1G shows as follow Figure 1-3-1 Front & Rear view of DWG2000-1G 1.3.1 Interface Table 1-3-1 Description of interface Interface Description WAN Indications blinking when connect successful LAN Indications blinking when connect successful SIM 1 SIM channel DC DC 12V 1.3.
DWG2000-1G User Manual 1.4 Functions and Features 1.4.1 Protocol Standard Supported Standard SIP and MGCP(option) protocol; Simple Traversal of UDP over NATs (STUN); Point-to-point protocol over Ethernet (PPPoE); Hypertext Transfer Protocol (HTTP); Dynamic Host Configuration Protocol (DHCP); Domain Name System (DNS); GSM; ITU-T G.711α-Law/μ-Law、G.723.1、G.729AB; 1.4.
DWG2000-1G User Manual 1.4.4 General Hardware Specification Power Supply:AC100~240V 50/60HZ DC12V/1A Temperature: 0~40 ℃(Operation), -20~80 ℃(storage) Humidity: 5%~90%RH, Power Consumption: 5W Dimensions: 112(W) x76(D) x24(H) mm Net weight: 0.7kg _______________________________________________________________________________ Dinstar Technologies Co., Ltd. 7 VoIPon www.voipon.co.uk sales@voipon.co.
DWG2000-1G User Manual 2. Equipment Installation This chapter mainly introduces DWG2000-1G hardware installation and connection of equipment. 2.1 Installation Notice DWG2000-1G uses DC12V power. Power supply should ensure the reliability and stability,otherwise, it may damage the SIM card or device. In addition, make sure the power supply connects to ground bar well.
DWG2000-1G User Manual 2.2.2 Antenna Installation Take antenna connected in antenna interface of DWG which sign of "ANT" on 2.2.3 Cable Connection of Equipment DWG2000-1G works in Route mode Figure 2-2-1 DWG2000-1G connection _______________________________________________________________________________ Dinstar Technologies Co., Ltd. 9 VoIPon www.voipon.co.uk sales@voipon.co.
DWG2000-1G User Manual 3. Network Configuration In this chapter we will introduce the initial configuration of DWG2000-1G gateway. All of the network parameters of the gateway can be configured by IVR guidance. 3.
DWG2000-1G User Manual *198# Clear record *199# Setting Record. dial*199# start record(≤ 20s), then press # end the *111# Restart device recording 3.4 Static IP Configuration This chapter introduces IP configuration of DWG2000-1G through calling IVR. Assuming the IP address of a DWG2000-1G device is 172.16.0.100, subnet mask is 255.255.0.0, IP of gateway is 172.16.0.
DWG2000-1G User Manual 4. WEB configuration This charpter describes web configuration of DWG2000-1G. 4.1 Preparing WEB configuration includes the following components: network configuration, system information, mobile configuration and system configuration. 4.2 Access the System Through HTTP Enter IP address of DWG2000-1G in browser. The default IP of LAN port is 192.168.11.1.
DWG2000-1G User Manual 4.3 WEB Configuration DWG2000-1G WEB configuration interface consists of the navigation tree and the detail configuration interfaces. Figure 4-3-1 WEB introduce Go through navigation tree, user can check, view modify, and set the device configuration on the right of configuration interface. 4.4 System Information Figure 4-4-1 system information System information interface shows the basic information of status information, Mobile information and SIP information.
DWG2000-1G User Manual 4.4.1 System Information Figure 4-4-2 system information Table 4-4-1 Description of system information MAC Address Displays the current MAC of the gateway, for example: 00-1F-D6-1B-3D-02 Network Mode DWG2000-1G support two types network mode, which is bridge and route modes Network Shows IP address and subnet mask DNS Server Displays DNS server IP address in the same network with the gateway System Up Time shows the time period of the device running.
DWG2000-1G User Manual Signal Quality Displays the signal strength of in each channels of GSM / CDMA. 4.4.3 SIP Information Figure 4-4-4 SIP information Displays registration status information with Softswitch platform or SIP Server Table 4-4-3 Description of SIP information Port He corresponding number of GSM channel, DWG2000-1G has only 1 port.
DWG2000-1G User Manual 4.5.1 Local Network Under the route mode, WAN port connects with ADSL modem, and LAN port connects with local network. It will be used as a small switch when working in brigde mode. In this situation, user just need to configure the WAN parameter and DNS. User also need configure the LAN port if working in route mode.
DWG2000-1G User Manual Table 4-5-1 Description of Local network Work Mode Two options of route mode and bridge mode, default is bridge mode Link Speed & Duplex The 5 options are “Auto Detect”,” 10Mbps/Half Duplex”,”10Mbps/Full Duplex”, “100Mbps/Half Duplex” and “100Mbps/Full Duplex”. Default is “Auto Detect” Obtain IP Address Enable the device obtain IP Address automatically or not.
DWG2000-1G User Manual 4.5.3 DHCP Server Under “route mode”, DWG works as a router. Config DHCP serive to enable the DHCP service funcition of DWG, then DWG will works as a DHCP server. Figure 4-5-6 Configuration of DHCP service Table 4-5-2 Description of DHCP Server IP address Pool Determines the range of IP addess of other devices in this network IP Lease Time Sets the duration for how long the IP works with the specific IP.
DWG2000-1G User Manual 4.5.5 Forward Rules In some conditions, certain devices in LAN network need to provide channel communication with WAN network( e.g. certain computer in LAN network need to provide FTP service of channel 21 to WAN network). In this situation, Configuring forwarding rules to this device is necessary.
DWG2000-1G User Manual Table 4-5-4 Description of Static Route Dest IP Address Destination IP address the date packets will be sended Subnet Mask The Subnet Mask of Destination IP address Nexthop The Next Hop IP address if want to arrive the Destination IP addres 4.5.7 Qos Parameter Figure 4-5-10 Qos parameter If you want to use Qos,please select yes,and click save _______________________________________________________________________________ Dinstar Technologies Co., Ltd. 20 VoIPon www.voipon.
DWG2000-1G User Manual 4.6 Mobile Configuration 4.6.1 Basic Configuration Figure 4-6-1Basic Configuration Table 4-6-1 Description of Basic Configuration Dial Tone Gain It is the dial tone volume of call waiting, dial tone of mobile module when call out. Usually adopt the default configuration. Select Band Acording to carrier’s band standards. Standards are as belows: GSM: 850/900/1800/1900 MHz; CDMA: 800 MHz Remote API Enable API is provided for third party development with DLL and IAD components.
DWG2000-1G User Manual 4.6.2Mobile Figure 4-6-2 Mobile Configuration Table 4-6-2 Description of Mobile Configuration Mobile Number SIM card user ID of the channel. That must be configured when “one access No.” funciton enable. Enable Call This function is to limit the max call duration of channel. The max call Duration duration is between 1 to 65535 minutes. Limitation Maximum Call Defines a value by users. That will limit the SIM/UIM card’s total call Duration duration.
DWG2000-1G User Manual (via SMS) SMS to remind the users of the SIM remain time. Port Description It is the identification mark of SIM/UIM card in the designated SMS report. for Alarm The mobile phone No. of the SIM/UIM card is recommended to use as the port description for alarm, or any other string. SIM Remain Indicates the current sim remain time. It can’t modified Time Restore time Recovers the SIM remain time to initial value, the Maximum Call Duration. CLIR Caller ID display restrict.
DWG2000-1G User Manual 4.6.4 PIN Management Figure 4-6-4 PIN Management Detailed description as below: Table 4-6-4 Description of PIN Management PIN PIN is the password of SIM card personal identification. In the status of SIM card locked, PIN can be modified to prevent SIM card from being stolen. Select Port Selects the GSM/CDMA channel No. Old PIN code The previous PIN code New PIN code Inputs a new PIN code 4.6.
DWG2000-1G User Manual 4.6.6 SMS Figure 4-6-6 SMS sending Configurations are as below: Table 4-6-5 Description of SMS sending Select Port Users can select a defined channel or random channel to send SMS. Input the recevier’s mobile phone No to send SMS. Addressee Mobile phone No. of the receiver Message Content of the SMS. The length is limited to 300 characters. 4.6.
DWG2000-1G User Manual Table 4-6-6 Description of USSD Port Select the GSM channel to send USSD Display Display the result of sending USSD Input The area to input USSD code 4.6.8 Carrier Figure 4-6-8select Carrier This function is used to select carrier. Table 4-6-6 Description of select Carrier Select Port Select GSM channel,default Port 0 Select Mode There are two mode to select carrier,automatic and manual. Carrier List If you select manual mode,you can select carrier from carrier list.
DWG2000-1G User Manual 4.7 Routing Configuration 4.7.
DWG2000-1G User Manual Source Prefix All the caller number must match the source prefix. It specifies the source prefix allow to send call out Any: include anonymous, 0xxxx, 1[2-9]xxxx etc. 0xxxx: consist of some digits such as 015,08,09 1[3-8]6:consist of some prefix, include 136,146,156,166,176, 186 Destination Prefix All the called number must match the destination prefix, the call prefix indicates the connected number Any: include anonymous, 0xxxx, 1[2-9]xxxx etc.
DWG2000-1G User Manual Add a GSM to VoIP route. It indicates that the calls coming from Port Group 31 will match the prefix ”x.”, ”x.” is a wildcard string which will match any prefix except ”anonymous” calls. Meanwhile sending the calls destination IP 13 if called number match with destination prefix ”00”. Figure 4-7-3 Tel to IP routing Modify Add GSM to GSM route,its mainly used for saving the cost between two carriers.
DWG2000-1G User Manual 4.8 Manipulaton Configuration 4.8.1 IP->Tel Destination Numbers Figure 4-8-1 IP->Tel destination numbers manipulation Table 4-8-1 Description of IP->Tel destination numbers manipulation IP->Tel destination numbers manipulation It is an optional configuration item, and is used to add IP->Tel number change data. The IP->Tel Manipulation defined the rules of add, and deletion of called numbers, which are referenced by IP->Tel routing. Index It uniquely identifies a route.
DWG2000-1G User Manual Add an IP->Tel Manipulation, to change the called number from 2547888888 to 07888888 Figure 4-8-2 IP->Tel destination numbers manipulation modify It indecates that calls coming from IP Group will match the prefix ”any”, and the called nubmer whom match with the prefix ”2547” will delete 3 digits in front of it and replace it by digit ”0”. 4.8.
DWG2000-1G User Manual Source Prefix All the caller number must match the source prefix. It specifies the source prefix allow to send call out Any: include anonymous, 0xxxx, 1[2-9]xxxx etc. 0xxxx: consist of some digits such as 015,08,09 1[3-8]6:consist of some prefix, include 136,146,156,166,176, 186 Destination Prefix All the called number must match the destination prefix, the call prefix indicates the connected number Any: include anonymous, 0xxxx, 1[2-9]xxxx etc.
DWG2000-1G User Manual 4.8.3 Tel->IP Destination Numbers Figure 4-8-5 Tel->IP destination numbers manipulation Table 4-8-3 Description of Tel->IP destination numbers manipulation Tel->IP destination numbers manipulation It is an optional configuration item, and is used to add IP->Tel number change data. The IP->Tel Manipulation defined the rules of add, and deletion of called numbers, which are referenced by IP->Tel routing. Index It uniquely identifies a route.
DWG2000-1G User Manual Example Add an IP->Tel Manipulation, to change the called number from 2547888888 to 07888888 Figure 4-8-6 Tel->IP destination numbers manipulation It indecates that calls coming from IP Group will match the prefix ”any”, and the called nubmer whom match with the prefix ”2547” will delete 3 digits in front of it and replace it by digit ”0”. _______________________________________________________________________________ Dinstar Technologies Co., Ltd. 34 VoIPon www.voipon.co.
DWG2000-1G User Manual 4.9 Operation 4.9.1 IP->Tel Operation Figure 4-9-1 IP->Tel Operation Table 4-9-1 Description of IP->Tel Operation IP->Tel Operation It is an optional configuration item. Operation configuration essentially involves allow, barring some IP and IP Group send calls to certain numbers. It includes: forbid call, call allowance, auto call, and password authentication. Index It uniquely identifies a route. Its value is assigned globally, ranging from 0 to 31.
DWG2000-1G User Manual Example Index 31: barring the certain calling number from IP 14 Figure 4-9-2 IP->Tel Operation Modify It indicates that calling party from IP 14 matched prefix 2877, and also called party matched prefix 07 are not allowed call out. The calls match this rule will be rejected by gateway. Index 29: definite a rule for IP 17 that all the calls must go with valid password authentication. Figure 4-9-3 IP->Tel Operation Modify 4.9.
DWG2000-1G User Manual Table 4-9-2 Description of Tel->IP Operation Tel->IP Operation It is an optional configuration item. Operation configuration essentially involves allow, barring some IP and IP Group send calls to certain numbers. It includes: forbid call, call allowance, auto call, and password authentication. Index It uniquely identifies a route. Its value is assigned globally, ranging from 0 to 31.
DWG2000-1G User Manual 4.10 IP Trunk Configuration 4.10.1 IP Trunk Figure 4-10-1 IP Trunk Table 4-10-1 Description of IP Trunk IP Trunk Add remote IP of softswitch, SIP server which will send call traffics to gateway. Index It uniquely identifies a route. Its value is assigned globally, ranging from 0 to 31. Description It describes the route for the ease of identification. Its value is character string IP It is an interworking parameter between the remote Softswitch and the SIP server.
DWG2000-1G User Manual 4.10.2 IP Trunk Group Figure 4-10-3 IP Trunk Group Table 4-10-2 Description of IP Trunk Group IP Trunk Group This configuration is optional, and is used to add the IP that have the same attributes to an IP group. The IP group will referenced by IP->Tel routing and number manipulation. Index It uniquely identifies a route. Its value is assigned globally, ranging from 0 to 31. Description It describes the route for the ease of identification.
DWG2000-1G User Manual 4.11 System Configuration 4.11.1 System Configuration Figure 4-11-1 System Configuration Table 4-11-1 Description of System Configuration Voice Prompt Language Configure the voice prompt of DWG., e.g. configure voice prompt of IP address success or failure. DWG supports English and Chinese. Users can customize other languages. The default setting is in Chinese. Provision configuration Provision is used to maintain the devices. E.g.
DWG2000-1G User Manual Provision Check Interval Default is 4 hours. Enable NTP NTP enable switch Primary NTP Server IP Can keep the default Secondary Provision NTP Can keep the default Server IP Time Zone The default is GMT +8:00, the user can adjusted accordingly according to their area 4.11.
DWG2000-1G User Manual Table 4-11-2 Description of Service Configuration Means the initial allocation of Channel when RTP voice stream transmit in LOCAL RTP PORT the IP network , in general, using the factory default values.
DWG2000-1G User Manual Means the code format when Voice transfer on IP network, support PCMA, PCMU, G.723.1 andG.729AB. Preferred Coders Note: when the preferred codec switch between G.723.1 and G.
DWG2000-1G User Manual Internet terminal Channel. This information is used for two host to set up UDP communication behind the same NAT router. The agreement defined by the RFC 3489 Select the name under the special needs , the most common way is use the CLID Mode default User ID Allow Outgoing Calls Refer to "SIP Configuration" -> "Is register" .
DWG2000-1G User Manual SIP Configuration Used for Configuring VoIP channel, add SIP Registry Platform and local SIP Channel, and configure SIP protocol and other related information Used for configure SIP server address and Channel, the address can be IP SIP Server Address, also can be a domain name (DNS should to be able to resolution), Address the details please advisory the service provider SIP Proxy Port Port default setting is 5060.
DWG2000-1G User Manual Table 4-11-3Description of Port Configuration Port Configuration Used to configure ports’ gain, Off-hook Auto-Dial, etc.
DWG2000-1G User Manual Digit Map Syntax: 1. Supported objects Digit: A digit from "0" to "9". Timer: The symbol "T" matching a timer expiry. DTMF: A digit, a timer, or one of the symbols "A", "B", "C", "D", "#", or "*". 2. Range [] One or more DTMF symbols enclosed between square brackets ("[" and "]"), but only one can be selected. 3. Range () One or more expressions enclosed between round brackets ("(" and ")"), but only one can be selected. 4. Separator |: Separated expressions or DTMF symbols. 5.
DWG2000-1G User Manual 2. [2-8] xxxxxx | 13xxxxxxxxx Means that first is "2","3","4","5","6","7" or "8", followed by 6 digits; or first is 13, followed by 9 digits. 3. (13 | 15 | 18)xxxxxxxxx Means that first is "13","15" or "18", followed by 8 digits. 4. [1-357-9]xx Means that first is "1","2","3" or "5" or "7","8","9", followed by 2 digits. 4.12 Tools 4.12.
DWG2000-1G User Manual NOTE: the customize voice files can be recorded using Windows recording programs, the sound format is 8000Hz, 16 bit sampling in mono, with WAV format, size of files can not exceed 190KB 4.12.3 Data Backup Figure 4-12-3 Data backup Click 'Backup' for download configuration file to your computer. 4.12.4 Data Restore Figure 4-12-4 Data restore Send data file from your computer to the device 4.12.
DWG2000-1G User Manual Enable SysLog select yes to enable syslog client function Server Address Syslog Level Fill in the Syslog server IP Address here There are five level of syslog:NONE、DEBUG、NOTICE、WARNING、 ERROR, we urge you to select DEBUG. Send CDR If you select yes, DWG will send CDR to syslog server. 4.12.6 Login Password Figure 4-12-6 IVR Voice Prompt Upload When using web or telnet Configuration, please enter default user name and password. User can modify the login name and password. 4.12.
DWG2000-1G User Manual 5. FAQ 5.
DWG2000-1G User Manual 5.