Operating Guide
12 www.dimplex.com
FIREPLACE JUNCTION BOX
120 V
POWER
SUPPLY
(BREAKER
PANEL)
WHITE - N
BLACK – L1
WHITE – N
BLACK – L
GROUND - G
WALL
SWITCH
GROUND - G
5. Make sure all wires are secure
and do not protrude past the
ame panel, so as not to be
visible after nal assembly.
6. Continue to the nal assembly
instructions.
120V Installation - Plug Kit
WARNING: This heater is
not intended for use with an
extension cord. Plug the cord
directly into an ap propriate wall
receptacle.
To install a plug kit:
1. Locate the rear cover plate
about 12 in. (30.5 cm) from the
left side at the bottom (when
looking at the replace from the
back). Remove the 3 screws
that hold the plate (Figure 8).
2. Feed wire from plug kit into
opening and attach re-using the
3 screws from Step 1.
3. Connect the L wire from the unit
to the black wire of the plug kit.
4. Connect the N wire from the
replace to the white wire from
the plug kit.
5. Connect ground wire from the
replace to the green wire from
the plug kit.
6. Make sure all wire connections
are tight and that wires are
secured and do not protrude
past the ame panel, so as
not to be visible after nal
installation.
7. Continue to nal installation.
Figure 7
Fireplace Installation