Operating Guide

12 www.dimplex.com
FIREPLACE JUNCTION BOX
120 V
POWER
SUPPLY
(BREAKER
PANEL)
WHITE - N
BLACK – L1
WHITE – N
BLACK – L
GROUND - G
WALL
SWITCH
GROUND - G
5. Make sure all wires are secure
and do not protrude past the
ame panel, so as not to be
visible after nal assembly.
6. Continue to the nal assembly
instructions.
120V Installation - Plug Kit
WARNING: This heater is
not intended for use with an
extension cord. Plug the cord
directly into an ap propriate wall
receptacle.
To install a plug kit:
1. Locate the rear cover plate
about 12 in. (30.5 cm) from the
left side at the bottom (when
looking at the replace from the
back). Remove the 3 screws
that hold the plate (Figure 8).
2. Feed wire from plug kit into
opening and attach re-using the
3 screws from Step 1.
3. Connect the L wire from the unit
to the black wire of the plug kit.
4. Connect the N wire from the
replace to the white wire from
the plug kit.
5. Connect ground wire from the
replace to the green wire from
the plug kit.
6. Make sure all wire connections
are tight and that wires are
secured and do not protrude
past the ame panel, so as
not to be visible after nal
installation.
7. Continue to nal installation.
Figure 7
Fireplace Installation