How to Guide

www.dimplex.com 9
Fireplace Installation
!
NOTE: It is recommended
that the bottom of the unit
be mounted between 30 in.
(76.2 cm) and 40 in. (101.6 cm)
from the ground to maintain an
optimized viewing angle of the
ame.
WARNING: Do not attempt
to wire your own new circuits.
To reduce the risk of re,
electric shock or injury to
persons, always use a licensed
electrician.
WARNING: Make sure the
circuit on which the replace is
to be installed has the power
cut o󰀨 at the service panel until
installation is complete.
2. The unit is provided with an
installed ¾ in. (2.0 cm) trim.
Depending on the installation,
this trim can be removed by
removing the securing screws
and the 4 trim pieces.
3. Ensuring a minimum of 18 in.
(46.7 cm) of slack, route the
supply power wire through a
cable clamp (not included) and
in the opening in the back of the
unit. (Figure 4)
Figure 4
Grounding
Screw
Cable Clamp
4. Lift replace, from the bottom
and the handles located on the
back, and insert into opening to
the desired depth.
5. Using a bubble level (supplied)
ensure that the replace is level
within the framing. Adjust as
required.
6. Drive four supplied mounting
screws through the four
mounting holes located on the
inside surface of the replace
chassis, into wall studs
(Figure 5).