Warranty
10 www.dimplex.com
Figure 5
Mounting Holes
Main Control Board
Flame Panel
Permanent Heat Disable
The replace heater can be
permanently disabled by
removing the electronic jumper on
the main control board. Disable
the heater before any other
installation takes place.
To disable the heater:
1. Locate the main control board
(Figure 5).
2. Pull out the electronic jumper
(shunt). The marking beside the
jumper is "HT EN" (Figure 6).
Figure 6
HT EN
Fireplace Installation (continued)