Owner's Manual

9
Wall Control Installation
Hard Wired Power Supplied
Installation
Before starting this installation,
it is helpful to initialize the Wall
Switch Remote Control with your
rebox (see Initialization section).
You should have the following
items ready and prepared:
Installed standard wall device
box with a minimum depth of
2.5 inch (6.35 cm).
A 24V~ power source leading
to the device box. Possible
sources could be a 24V~ door-
bell circuit or a Class 2 24V~
transformer.
The 24V~ wire leads coming
into the device box should have
between 4 and 6 inches (10-15
cm) of slack left inside the box
to allow for ease of installation
and/or servicing.
You may also leave the sup-
plied AAA batteries in the
Controller. There is an internal
electronic bypass that will draw
on the hard wired power source
before the batteries.
1. Unpack the Wall Switch Re-
mote Control and all hardware
from its package.
2. Release the Controller from
Figure 8
Outer
Housing
Controller
Guides
Tracks
Figure 9
Controller
Flat head screws
(supplied)
Wall Box
Outer Housing