Instruction Manual
  9
 Wall Control Installation 
to complete the installation 
and to blend the installation in 
with your choice of decor. 
Hard Wired Power Supplied 
Installation
Before starting this installation, 
it is helpful to initialize the Wall 
Switch Remote Control with your 
rebox (see Initialization section). 
You should have the following 
items ready and prepared:
Installed standard wall device • 
box with a minimum depth of 
2.5 inch (6.35 cm).
A 24V~ power source leading • 
to the device box. Possible 
sources could be a 24V~ 
doorbell circuit or a Class 2 
24V~ transformer.
The 24V~ wire leads coming • 
into the device box should have         
between 4 and 6 inches (10-15 
cm) of slack left inside the box 
to allow for ease of installation 
and/or servicing.
You may also leave the • 
supplied AAA batteries in the 
Controller. There is an internal 
electronic bypass that will draw 
on the hard wired power source 
before the batteries.
Figure 8
Outer
Housing
Controller
Guides
Tracks
Figure 9
Controller
Flat head screws
(supplied)
Wall Box
Outer Housing
head screws (supplied) as 
shown in Figure 9.
7.  Attach your choice of Decora 
style faceplate (not supplied) 